Your browser doesn't support javascript.
loading
Long-term outcome of defibrillator recipients included in the federal audit conducted by the Department of Justice.
Shariff, Nasir; Rahim, Shiraz; Jain, Sandeep; Barrington, William; Saba, Samir.
Affiliation
  • Shariff N; Department of Medicine, Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
  • Rahim S; Department of Medicine, Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
  • Jain S; Department of Medicine, Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
  • Barrington W; Department of Medicine, Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
  • Saba S; Department of Medicine, Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania. Electronic address: sabas@upmc.edu.
Am J Cardiol ; 114(5): 723-6, 2014 Sep 01.
Article in En | MEDLINE | ID: mdl-25023911
ABSTRACT
Institutions across the United States have been subjected to a federal audit for defibrillator implantable cardioverter defibrillator [ICD] implantations that violated the Centers for Medicare and Medicaid payment policy. We examined the long-term outcome of ICD recipients whose implantation procedures were audited by the Department of Justice (DOJ). Patients (n = 225) included in the DOJ audit at the University of Pittsburgh Medical Center between the years 2003 and 2010 were followed to the end point of all-cause mortality. A cohort of 206 consecutive and contemporary ICD recipients not included in the federal audit served as controls. Compared with the controls, the audited cases were older (p <0.001), had more preserved ejection fraction (p <0.001), and were less likely to be implanted for a primary prevention indication (p = 0.001). They also had significantly shorter time from myocardial infarction (p <0.001) or revascularization (p <0.001) to ICD implantation. Over a median follow-up of 3.6 years, 187 patients died and 71 received ICD therapy for ventricular arrhythmias. Patients whose cases were audited had worse survival compared with controls (hazard ratio 1.41, 95% confidence interval 1.05 to 1.90, p = 0.023) even after correcting for differences in baseline characteristics (hazard ratio 1.46, 95% confidence interval 1.05 to 2.02, p = 0.023). Rates of appropriate and inappropriate ICD therapies were similar between the audited cases and controls. In conclusion, patients whose ICD implantations were audited by the DOJ have worse long-term survival compared with nonaudited control patients. These data support compliance with the Centers for Medicare and Medicaid guidelines when the individual patient's clinical condition allows it.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Social Justice / Tachycardia, Ventricular / Federal Government / Defibrillators / Clinical Audit / Government Programs Type of study: Clinical_trials / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Aspects: Determinantes_sociais_saude Limits: Aged / Humans / Male Country/Region as subject: America do norte Language: En Journal: Am J Cardiol Year: 2014 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Social Justice / Tachycardia, Ventricular / Federal Government / Defibrillators / Clinical Audit / Government Programs Type of study: Clinical_trials / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Aspects: Determinantes_sociais_saude Limits: Aged / Humans / Male Country/Region as subject: America do norte Language: En Journal: Am J Cardiol Year: 2014 Document type: Article