Thulium laser (RevoLix) vaporesection versus vapoenucleation with morcellator (Piranha) for the treatment of benign prostatic obstruction: a propensity-matched multicenter analysis.
Int J Urol
; 21(11): 1156-61, 2014 Nov.
Article
in En
| MEDLINE
| ID: mdl-25040293
OBJECTIVES: To compare the efficacy and safety of vaporesection without a morcellator, and vapoenucleation with a morcellator in thulium laser prostatectomy for the treatment of benign prostatic obstruction. METHODS: Between March 2010 and January 2013, 405 patients underwent thulium:yttrium-aluminium-garnet laser prostatectomy. Among these patients, 150 patients who underwent thulium:yttrium-aluminium-garnet laser prostatectomy without a morcellator (n = 75) or with a morcellator (n = 75) were analyzed in a propensity matching study. Outcome measures included International Prostate Symptom Score, quality of life score, maximum flow rate, postvoid residual, total operating time, laser time and resected tissue weight. RESULTS: No significant differences were noted between the thulium:yttrium-aluminium-garnet laser prostatectomy without a morcellator and thulium:yttrium-aluminium-garnet laser prostatectomy with a morcellator groups, including the prostate volume (50.3 vs 51.9 mL) and postoperative prostate volume (22.4 vs 18.7 mL). However, there were differences between the groups in total operating time (72.8 vs 61.0 min, P = 0.023) and laser activating time (24.5 vs 19.9 min, P = 0.037). Thulium:yttrium-aluminium-garnet laser prostatectomy with a morcellator showed greater resected tissue volume than thulium:yttrium-aluminium-garnet laser prostatectomy without a morcellator (9.0 vs 18.2 g, P = 0.029). There were also significant differences in total retrieval efficiency (1.14 vs 1.67 g/min, P = 0.031). There were no significant differences in improvement of International Prostate Symptom Score, quality of life scores and urodynamic findings between the two groups, except for the International Prostate Symptom Score (11.2 vs 7.3, P = 0.028) at 6 weeks after surgery. CONCLUSION: Thulium:yttrium-aluminium-garnet laser prostatectomy with a morcellator provides superior reduction of prostate volume and better short-term clinical outcomes than thulium:yttrium-aluminium-garnet laser prostatectomy without a morcellator in the treatment of patients with benign prostatic obstruction. Furthermore, thulium:yttrium-aluminium-garnet laser prostatectomy with a morcellator can offer a shorter operative time.
Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Prostatectomy
/
Prostatic Hyperplasia
/
Urinary Retention
/
Laser Therapy
/
Lasers, Solid-State
Type of study:
Etiology_studies
/
Observational_studies
/
Risk_factors_studies
Aspects:
Patient_preference
Limits:
Aged
/
Aged80
/
Humans
/
Male
/
Middle aged
Language:
En
Journal:
Int J Urol
Journal subject:
UROLOGIA
Year:
2014
Document type:
Article
Country of publication:
Australia