Onyx-HD 500 Embolization of a Traumatic Internal Carotid Artery Pseudoaneurysm after Transsphenoidal Surgery.
J Neuroimaging
; 25(4): 656-9, 2015.
Article
in En
| MEDLINE
| ID: mdl-25682851
BACKGROUND AND PURPOSE: Traumatic intracranial pseudoaneurysms present a challenge for treatment. Traditionally these lesions have required a deconstructive approach consisting of vessel sacrifice since their fragile nature often makes direct microsurgical repair or coil embolization hazardous. As a high-viscosity liquid embolic agent that results in immediate, vessel sparing aneurysm occlusion, Onyx-HD 500 represents a uniquely efficacious tool for this clinical situation. CASE SUMMARY: We report the case of a 56-year-old right-handed gentleman who suffered a vascular injury to the ICA during revision transsphenoidal surgery for a recurrent pituitary macroadenoma. The patient was initially treated with nasal packing, but after recurrent episodes of epistaxis and a CT angiogram demonstrating a large traumatic ICA pseudoaneurysm, the patient was referred for invasive treatment. Given the presumed fragility of the lesion, embolization with Onyx-HD 500 was chosen in order to safely achieve immediate aneurysm occlusion without the need for vessel sacrifice. After an early recurrence due to incomplete initial embolization, the patient went on to complete occlusion without further hemorrhage. CONCLUSION: This case illustrates the utility of a high-viscosity liquid embolic agent in providing immediate protection from rehemorrhage by occluding a large ruptured pseudoaneurysm of the proximal intracranial ICA, while sparing the parent artery.
Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Polyvinyls
/
Dimethyl Sulfoxide
/
Neurosurgical Procedures
/
Carotid Artery Injuries
/
Embolization, Therapeutic
Limits:
Humans
/
Male
/
Middle aged
Language:
En
Journal:
J Neuroimaging
Journal subject:
DIAGNOSTICO POR IMAGEM
/
NEUROLOGIA
Year:
2015
Document type:
Article
Country of publication:
United States