Your browser doesn't support javascript.
loading
Evaluation of an MPN test for the rapid enumeration of Pseudomonas aeruginosa in hospital waters.
Sartory, David P; Pauly, Danièle; Garrec, Nathalie; Bonadonna, Lucia; Semproni, Maurizio; Schell, Christiane; Reimann, Annika; Firth, Susan J; Thom, Christopher; Hartemann, Philippe; Exner, Martin; Baldauf, Henning; Lee, Susanne; Lee, John V.
Affiliation
  • Sartory DP; SWM Consulting, 7 Sunnybank, Little Ness, Shrewsbury SY4 2LQ, UK E-mail: david.sartory@tesco.net.
  • Pauly D; Département Environnement et Santé Publique - INSERM EA 7298 INGRES - Faculté de Médecine, Lorraine University Medical School, Vandoeuvre les Nancy, France.
  • Garrec N; Centre Scientifique et Technique du Bâtiment, 11 rue Henri Picherit, BP 82341-44323, Nantes Cedex 3, France.
  • Bonadonna L; Istituto Superiore di Sanità, Reparto di Microbiologia e Virologia Ambientale e Wellness Dipartimento di Ambiente e Connessa Prevenzione Primaria, Viale Regina Elena 299, Rome 00161, Italy.
  • Semproni M; Istituto Superiore di Sanità, Reparto di Microbiologia e Virologia Ambientale e Wellness Dipartimento di Ambiente e Connessa Prevenzione Primaria, Viale Regina Elena 299, Rome 00161, Italy.
  • Schell C; Hygiene-Institut des Ruhrgebiets, Institut für Umwelthygiene und Toxikologie, Rotthauser Str. 21, Gelsenkirchen 45879, Germany.
  • Reimann A; Hygiene-Institut des Ruhrgebiets, Institut für Umwelthygiene und Toxikologie, Rotthauser Str. 21, Gelsenkirchen 45879, Germany.
  • Firth SJ; ALcontrol Laboratories, 7 & 8 Aspen Court, Bessemer Way, Rotherham S60 1FB, UK.
  • Thom C; Latis Scientific Ltd, 6 Bridgewater Square, London EC2Y 8AG, UK.
  • Hartemann P; Département Environnement et Santé Publique - INSERM EA 7298 INGRES - Faculté de Médecine, Lorraine University Medical School, Vandoeuvre les Nancy, France.
  • Exner M; Universitätsklinikum Bonn, Institut für Hygiene und Öffentliche Gesundheit, Sigmund-Freud-Straße 25, Bonn 53105, Germany.
  • Baldauf H; QuoData GmbH, Kaitzer Str. 135, Dresden D-01187, Germany.
  • Lee S; Leegionella Ltd, Edgemoor Cottage, Rockford, Ringwood BH24 3NA, UK.
  • Lee JV; Leegionella Ltd, Edgemoor Cottage, Rockford, Ringwood BH24 3NA, UK.
J Water Health ; 13(2): 427-36, 2015 Jun.
Article in En | MEDLINE | ID: mdl-26042975
ABSTRACT
In this study, the performance of a new most probable number (MPN) test (Pseudalert(®)/Quanti-Tray(®)) for the enumeration of Pseudomonas aeruginosa from hospital waters was compared with both international and national membrane filtration-based culture methods for P. aeruginosa ISO 162662006 and UK The Microbiology of Drinking Water - Part 8 (MoDW Part 8), which both use Pseudomonas CN agar. The comparison based on the calculation of mean relative differences between the two methods was conducted according to ISO 179942014. Using both routine hospital water samples (80 from six laboratories) and artificially contaminated samples (192 from five laboratories), paired counts from each sample and the enumeration method were analysed. For routine samples, there were insufficient data for a conclusive assessment, but the data do indicate at least equivalent performance of Pseudalert(®)/Quanti-Tray(®). For the artificially contaminated samples, the data revealed higher counts of P. aeruginosa being recorded by Pseudalert(®)/Quanti-Tray(®). The Pseudalert(®)/Quanti-Tray(®) method does not require confirmation testing for atypical strains of P. aeruginosa, saving up to 6 days of additional analysis, and has the added advantage of providing confirmed counts within 24-28 hours incubation compared to 40-48 hours or longer for the ISO 16266 and MoDW Part 8 methods.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pseudomonas aeruginosa / Water Microbiology / Bacteriological Techniques / Hospitals Type of study: Evaluation_studies Limits: Humans Language: En Journal: J Water Health Journal subject: SAUDE AMBIENTAL Year: 2015 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pseudomonas aeruginosa / Water Microbiology / Bacteriological Techniques / Hospitals Type of study: Evaluation_studies Limits: Humans Language: En Journal: J Water Health Journal subject: SAUDE AMBIENTAL Year: 2015 Document type: Article