Improving Multiple Sclerosis Plaque Detection Using a Semiautomated Assistive Approach.
van Heerden, J; Rawlinson, D; Zhang, A M; Chakravorty, R; Tacey, M A; Desmond, P M; Gaillard, F.
Affiliation
  • van Heerden J; From the Department of Radiology (J.v.H., P.M.D., F.G.), The Royal Melbourne Hospital and University of Melbourne, Parkville, Victoria, Australia jolandivh@hotmail.com.
  • Rawlinson D; Department of Electrical and Electronic Engineering (D.R., A.M.Z.), School of Engineering, University of Melbourne, Parkville, Victoria, Australia.
  • Zhang AM; Department of Electrical and Electronic Engineering (D.R., A.M.Z.), School of Engineering, University of Melbourne, Parkville, Victoria, Australia.
  • Chakravorty R; IBM Research (R.C.), Melbourne, Victoria, Australia.
  • Tacey MA; Melbourne EpiCentre (M.A.T.), The Royal Melbourne Hospital and Department of Medicine, University of Melbourne, Parkville, Victoria, Australia.
  • Desmond PM; From the Department of Radiology (J.v.H., P.M.D., F.G.), The Royal Melbourne Hospital and University of Melbourne, Parkville, Victoria, Australia.
  • Gaillard F; From the Department of Radiology (J.v.H., P.M.D., F.G.), The Royal Melbourne Hospital and University of Melbourne, Parkville, Victoria, Australia.
AJNR Am J Neuroradiol ; 36(8): 1465-71, 2015 Aug.
Article in En | MEDLINE | ID: mdl-26089318
ABSTRACT
BACKGROUND AND

PURPOSE:

Treating MS with disease-modifying drugs relies on accurate MR imaging follow-up to determine the treatment effect. We aimed to develop and validate a semiautomated software platform to facilitate detection of new lesions and improved lesions. MATERIALS AND

METHODS:

We developed VisTarsier to assist manual comparison of volumetric FLAIR sequences by using interstudy registration, resectioning, and color-map overlays that highlight new lesions and improved lesions. Using the software, 2 neuroradiologists retrospectively assessed MR imaging MS comparison study pairs acquired between 2009 and 2011 (161 comparison study pairs met the study inclusion criteria). Lesion detection and reading times were recorded. We tested inter- and intraobserver agreement and comparison with original clinical reports. Feedback was obtained from referring neurologists to assess the potential clinical impact.

RESULTS:

More comparison study pairs with new lesions (reader 1, n = 60; reader 2, n = 62) and improved lesions (reader 1, n = 28; reader 2, n = 39) were recorded by using the software compared with original radiology reports (new lesions, n = 20; improved lesions, n = 5); the difference reached statistical significance (P < .001). Interobserver lesion number agreement was substantial (≥1 new lesion κ = 0.87; 95% CI, 0.79-0.95; ≥1 improved lesion κ = 0.72; 95% CI, 0.59-0.85), and overall interobserver lesion number correlation was good (Spearman ρ new lesion = 0.910, improved lesion = 0.774). Intraobserver agreement was very good (new lesion κ = 1.0, improved lesion κ = 0.94; 95% CI, 0.82-1.00). Mean reporting times were <3 minutes. Neurologists indicated retrospective management alterations in 79% of comparative study pairs with newly detected lesion changes.

CONCLUSIONS:

Using software that highlights changes between study pairs can improve lesion detection. Neurologist feedback indicated a likely impact on management.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Software / Magnetic Resonance Imaging / Image Interpretation, Computer-Assisted / Neuroimaging / Multiple Sclerosis Type of study: Diagnostic_studies / Guideline / Observational_studies Limits: Adult / Humans / Male Language: En Journal: AJNR Am J Neuroradiol Year: 2015 Document type: Article Affiliation country: Australia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Software / Magnetic Resonance Imaging / Image Interpretation, Computer-Assisted / Neuroimaging / Multiple Sclerosis Type of study: Diagnostic_studies / Guideline / Observational_studies Limits: Adult / Humans / Male Language: En Journal: AJNR Am J Neuroradiol Year: 2015 Document type: Article Affiliation country: Australia