Your browser doesn't support javascript.
loading
Performance analysis of a dedicated breast MR-HIFU system for tumor ablation in breast cancer patients.
Deckers, R; Merckel, L G; Denis de Senneville, B; Schubert, G; Köhler, M; Knuttel, F M; Mali, W P Th M; Moonen, C T W; van den Bosch, M A A J; Bartels, L W.
Affiliation
  • Deckers R; Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands.
Phys Med Biol ; 60(14): 5527-42, 2015 Jul 21.
Article in En | MEDLINE | ID: mdl-26133986
MR-guided HIFU ablation is a promising technique for the non-invasive treatment of breast cancer. A phase I study was performed to assess the safety and treatment accuracy and precision of MR-HIFU ablation in breast cancer patients (n=10) using a newly developed MR-HIFU platform dedicated to applications in the breast. In this paper a technical analysis of the performance of the dedicated breast MR-HIFU system during breast tumors ablation is described. The main points of investigation were the spatial targeting accuracy and precision of the system and the performance of real-time respiration-corrected MR thermometry.The mean targeting accuracy was in the range of 2.4-2.6 mm, whereas the mean targeting precision was in the range of 1.5-1.8 mm. To correct for respiration-induced magnetic field fluctuations during MR temperature mapping a look-up-table (LUT)-based correction method was used. An optimized procedural sedation protocol in combination with the LUT-based correction method allowed for precise MR thermometry during the ablation procedure (temperature standard deviation <3 °C). No unwanted heating in the near field (i.e. skin) nor in the far field (pectoral muscle) was detected.The newly developed dedicated breast MR-HIFU system allows for safe, accurate and precise ablation of breast tumors.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Image Processing, Computer-Assisted / Breast Neoplasms / Magnetic Resonance Imaging, Interventional / High-Intensity Focused Ultrasound Ablation / Thermometry Type of study: Guideline / Observational_studies Limits: Female / Humans Language: En Journal: Phys Med Biol Year: 2015 Document type: Article Affiliation country: Netherlands Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Image Processing, Computer-Assisted / Breast Neoplasms / Magnetic Resonance Imaging, Interventional / High-Intensity Focused Ultrasound Ablation / Thermometry Type of study: Guideline / Observational_studies Limits: Female / Humans Language: En Journal: Phys Med Biol Year: 2015 Document type: Article Affiliation country: Netherlands Country of publication: United kingdom