Your browser doesn't support javascript.
loading
Clinical and radiographic outcomes of a trabecular titanium™ acetabular component in hip arthroplasty: results at minimum 5 years follow-up.
Perticarini, Loris; Zanon, Giacomo; Rossi, Stefano Marco Paolo; Benazzo, Francesco M.
Affiliation
  • Perticarini L; Clinica Ortopedica e Traumatologica, Università degli Studi di Pavia, Fondazione IRCCS Policlinico San Matteo, Pavia, Viale Camillo Golgi 19, 27100, Pavia, Italy. loris.perticarini@gmail.com.
  • Zanon G; Clinica Ortopedica e Traumatologica, Università degli Studi di Pavia, Fondazione IRCCS Policlinico San Matteo, Pavia, Viale Camillo Golgi 19, 27100, Pavia, Italy. zanon.g@libero.it.
  • Rossi SM; Clinica Ortopedica e Traumatologica, Università degli Studi di Pavia, Fondazione IRCCS Policlinico San Matteo, Pavia, Viale Camillo Golgi 19, 27100, Pavia, Italy. rossi.smp@gmail.com.
  • Benazzo FM; Clinica Ortopedica e Traumatologica, Università degli Studi di Pavia, Fondazione IRCCS Policlinico San Matteo, Pavia, Viale Camillo Golgi 19, 27100, Pavia, Italy. fbenazzo@unipv.it.
BMC Musculoskelet Disord ; 16: 375, 2015 Dec 03.
Article in En | MEDLINE | ID: mdl-26634830
ABSTRACT

BACKGROUND:

Aim of this prospective study was to evaluate mid-term clinical and radiographic outcomes in total hip arthroplasty using an acetabular cup made of an innovative biomaterial, Trabecular Titanium™, whose highly porous structure and mechanical properties have been designed to mimic those of the natural bone, thus promoting a more physiological load transfer and a more durable fixation.

METHODS:

Between September 2007 and November 2009, 134 total hip replacements and eight revisions were carried out using DELTA-TT primary cups (Lima Corporate, Villanova di San Daniele del Friuli, Italy) in 133 consecutive patients. Mean age was 57.5 ± 14.7 SD (18-92) years. Diagnosis was primarily hip osteoarthritis in 85 (63 %) cases, developmental dysplasia of the hip (DDH) in 24 (18 %) and hip avascular necrosis (AVN) in 10 (7 %). All the revision procedures were due to aseptic loosening of the original implant. Approval of the Institutional Review Board of the IRCCS Policlinico San Matteo in Pavia was obtained for this study.

RESULTS:

Mean follow-up was 72.7 ± 7.9 SD (60-86) months. Average Harris Hip Score (HHS) significantly increased from 44.2 ± 5.4 SD (35-52) preoperatively to 95.9 ± 3.5 SD (88-100) at the last follow-up. No major post-operative complications were observed. 99.3 % of the acetabular components were radiographically stable at the last follow-up, without any radiolucent lines, sclerotic areas or periprosthetic osteolysis. Kaplan-Meier survival rate was 99.3 % at 5 years (95 % confidence interval).

CONCLUSIONS:

This first account on the mid-term clinical performance of the DELTA-TT cup shows primary and secondary stability, thus representing an optimal solution for patients with high demands or affected by severe hip conditions.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthroplasty, Replacement, Hip / Hip Joint / Hip Prosthesis Type of study: Diagnostic_studies / Observational_studies Limits: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: BMC Musculoskelet Disord Journal subject: FISIOLOGIA / ORTOPEDIA Year: 2015 Document type: Article Affiliation country: Italy

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthroplasty, Replacement, Hip / Hip Joint / Hip Prosthesis Type of study: Diagnostic_studies / Observational_studies Limits: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: BMC Musculoskelet Disord Journal subject: FISIOLOGIA / ORTOPEDIA Year: 2015 Document type: Article Affiliation country: Italy