Your browser doesn't support javascript.
loading
From Korotkoff and Marey to automatic non-invasive oscillometric blood pressure measurement: does easiness come with reliability?
Benmira, A; Perez-Martin, A; Schuster, I; Aichoun, I; Coudray, S; Bereksi-Reguig, F; Dauzat, M.
Affiliation
  • Benmira A; a Vascular Medicine and Laboratory , Nimes University Hospital, Montpellier University , Nimes , France.
  • Perez-Martin A; b Biomedical Engineering Laboratory, Faculty of Technology , Aboubekr Belkaid University , Tlemcen , Algeria.
  • Schuster I; a Vascular Medicine and Laboratory , Nimes University Hospital, Montpellier University , Nimes , France.
  • Aichoun I; a Vascular Medicine and Laboratory , Nimes University Hospital, Montpellier University , Nimes , France.
  • Coudray S; a Vascular Medicine and Laboratory , Nimes University Hospital, Montpellier University , Nimes , France.
  • Bereksi-Reguig F; a Vascular Medicine and Laboratory , Nimes University Hospital, Montpellier University , Nimes , France.
  • Dauzat M; b Biomedical Engineering Laboratory, Faculty of Technology , Aboubekr Belkaid University , Tlemcen , Algeria.
Expert Rev Med Devices ; 13(2): 179-89, 2016.
Article in En | MEDLINE | ID: mdl-26641026
The auscultatory technique remains the point of reference for the validation of non-invasive blood pressure measurement devices, although the exact origin of the Korotkoff sounds is still debated and comparison with intra-arterial measurement shows limits and pitfalls. Automatic oscillometric devices are now widely used by nurses, physicians, and patients. However, many available devices have not been duly validated. Moreover, they calculate systolic and diastolic blood pressures using undisclosed algorithms. Therefore, these devices are not interchangeable, and their reliability may be questionable in some clinical situations. Nevertheless, oscillometry is increasingly used, beside NIBP, for the assessment of central blood pressure and systemic arterial wall stiffness. Awareness of its limits and causes of error is all the more necessary.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Oscillometry / Blood Pressure / Blood Pressure Determination Limits: Humans Language: En Journal: Expert Rev Med Devices Journal subject: DIAGNOSTICO POR IMAGEM / TERAPEUTICA Year: 2016 Document type: Article Affiliation country: France Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Oscillometry / Blood Pressure / Blood Pressure Determination Limits: Humans Language: En Journal: Expert Rev Med Devices Journal subject: DIAGNOSTICO POR IMAGEM / TERAPEUTICA Year: 2016 Document type: Article Affiliation country: France Country of publication: United kingdom