Neonatal complications associated with use of fetal scalp electrode: a retrospective study.
Kawakita, T; Reddy, U M; Landy, H J; Iqbal, S N; Huang, C-C; Grantz, K L.
Affiliation
  • Kawakita T; Obstetrics and Gynecology, MedStar Washington Hospital Center, Washington, DC, USA. tetsuya.x.kawakita@gunet.georgetown.edu.
  • Reddy UM; Obstetrics and Gynecology, MedStar Washington Hospital Center, Washington, DC, USA.
  • Landy HJ; Obstetrics and Gynecology, MedStar Georgetown University Hospital, Washington, DC, USA.
  • Iqbal SN; Obstetrics and Gynecology, MedStar Washington Hospital Center, Washington, DC, USA.
  • Huang CC; Department of Biostatistics and Epidemiology, MedStar Health Research Institute, Hyattsville, MD, USA.
  • Grantz KL; Obstetrics and Gynecology, MedStar Washington Hospital Center, Washington, DC, USA.
BJOG ; 123(11): 1797-803, 2016 Oct.
Article in En | MEDLINE | ID: mdl-26643181
ABSTRACT

OBJECTIVES:

To estimate the incidence and risk of complications associated with a fetal scalp electrode and to determine whether its application in the setting of operative vaginal delivery was associated with increased neonatal morbidity.

DESIGN:

Retrospective cohort study.

SETTING:

Twelve clinical centers with 19 hospitals across nine American Congress of Obstetricians and Gynecologists US districts. POPULATION Women in the USA.

METHODS:

We evaluated 171 698 women with singleton deliveries ≥ 23 weeks of gestation in a secondary analysis of the Consortium on Safe Labor study between 2002 and 2008, after excluding conditions that precluded fetal scalp electrode application such as prelabour caesarean delivery. Secondary analysis limited to operative vaginal deliveries ≥ 34 weeks of gestation was also performed. MAIN OUTCOME

MEASURES:

Incidences and adjusted odds ratios with 95% confidence intervals of neonatal complications were calculated, controlling for maternal characteristics, delivery mode and pregnancy complications.

RESULTS:

Fetal scalp electrode was used in 37 492 (22%) of deliveries. In non-operative vaginal delivery, fetal scalp electrode was associated with increased risk of injury to scalp due to birth trauma (1.2% versus 0.9%; adjusted odds ratios 1.62; 95% confidence intervals 1.41-1.86) and cephalohaematoma (1.0% versus 0.9%; adjusted odds ratios 1.57; 95% confidence intervals 1.36-1.83). Neonatal complications were not significantly different comparing fetal scalp electrode with vacuum-assisted vaginal delivery and vacuum-assisted vaginal delivery alone or comparing fetal scalp electrode with forceps-assisted vaginal delivery and forceps-assisted vaginal delivery alone.

CONCLUSIONS:

We found increased neonatal morbidity with fetal scalp electrode though the absolute risk was very low. It is possible that these findings reflect an underlying indication for its use. Our findings support the use of fetal scalp electrodes when clinically indicated. TWEETABLE ABSTRACT Neonatal risks associated with fetal scalp electrode use were low (injury to scalp 1.2% and cephalohaematoma 1.0%).
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Scalp / Birth Injuries / Cardiotocography / Delivery, Obstetric / Electrodes Type of study: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Female / Humans / Newborn / Pregnancy Country/Region as subject: America do norte Language: En Journal: BJOG Journal subject: GINECOLOGIA / OBSTETRICIA Year: 2016 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Scalp / Birth Injuries / Cardiotocography / Delivery, Obstetric / Electrodes Type of study: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Female / Humans / Newborn / Pregnancy Country/Region as subject: America do norte Language: En Journal: BJOG Journal subject: GINECOLOGIA / OBSTETRICIA Year: 2016 Document type: Article Affiliation country: United States