Your browser doesn't support javascript.
loading
A Randomized Comparison of Hemoglobin Content-Based Versus Standard (Unit-Based) Red Blood Cell Transfusion Policy.
Atilla, Erden; Toprak, Selami Koçak; Civriz Bozdag, Sinem; Topçuoglu, Pervin; Arslan, Önder.
Affiliation
  • Atilla E; Ankara University Faculty of Medicine, Department of Hematology, Ankara, Turkey.
Turk J Haematol ; 34(3): 244-249, 2017 Aug 02.
Article in En | MEDLINE | ID: mdl-27149653
ABSTRACT

OBJECTIVE:

The hemoglobin (Hb) content of packed red blood cells (pRBCs) differs in standard volume units. The pRBC transfusions are based on the number of units routinely. We aimed to use pRBCs according to total Hb content and compare the rates of achieving the target Hb concentration levels with the current transfusion practice. MATERIALS AND

METHODS:

Eighty-nine patients (55 males and 34 females) with median age of 46 years (range 19-75) were enrolled, and of 178 transfusion episodes, 92 were randomized to the Hb content based-study group and 86 to the unit-based control group. Fifty-one patients were evaluated by 1 and rest of the patients by ≥2 episodes (median 3; range 1-7). Suitable pRBCs were detected by the Hemosoft Blood Banking Management & Information System. In the Hb content-based study group, to reduce the number of units, the required Hb was calculated by recipients' height, weight, and Hb levels. When no appropriate units could be found within the inventory, the actual ordered number of units was sent to clinics, as was done for the control group.

RESULTS:

In the study group totally, 38 units of pRBCs were transfused with a reduction of 19.8% (38/192) from the original order. The success of finding the matched Hb content was statistically increased with low weight and height and high pRBC storage. The Hb content of transfused pRBC units was significantly higher in the study group than the control group. The ratio of achieving the target Hb level was statistically similar in the control and study group (p=0.125), the successful and unsuccessful group (p=0.325), and the control and unsuccessful group (p=0.438). The relation between the shelf-life of the pRBC units and the rate of achieving the target Hb level was found to be similar between groups (p=0.782).

CONCLUSION:

The number of pRBC transfusions can be minimized since we clearly demonstrated that the efficacy of Hb content-based transfusion is similar to that of unit-based transfusion.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Hemoglobins / Erythrocyte Transfusion Type of study: Clinical_trials / Observational_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Turk J Haematol Year: 2017 Document type: Article Affiliation country: Turkey

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Hemoglobins / Erythrocyte Transfusion Type of study: Clinical_trials / Observational_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Turk J Haematol Year: 2017 Document type: Article Affiliation country: Turkey
...