Your browser doesn't support javascript.
loading
Development of a computational model for macroscopic predictions of device-induced thrombosis.
Taylor, Joshua O; Meyer, Richard S; Deutsch, Steven; Manning, Keefe B.
Affiliation
  • Taylor JO; Department of Biomedical Engineering, The Pennsylvania State University, 205 Hallowell Building, University Park, PA, 16802, USA.
  • Meyer RS; Applied Research Laboratory, The Pennsylvania State University, State College, PA, USA.
  • Deutsch S; Applied Research Laboratory, The Pennsylvania State University, State College, PA, USA.
  • Manning KB; Applied Research Laboratory, The Pennsylvania State University, State College, PA, USA.
Biomech Model Mechanobiol ; 15(6): 1713-1731, 2016 12.
Article in En | MEDLINE | ID: mdl-27169403
ABSTRACT
While cardiovascular device-induced thrombosis is associated with negative patient outcomes, the convoluted nature of the processes resulting in a thrombus makes the full thrombotic network too computationally expensive to simulate in the complex geometries and flow fields associated with devices. A macroscopic, continuum computational model is developed based on a simplified network, which includes terms for platelet activation (chemical and mechanical) and thrombus deposition and growth in regions of low wall shear stress (WSS). Laminar simulations are performed in a two-dimensional asymmetric sudden expansion geometry and compared with in vitro thrombus size data collected using whole bovine blood. Additionally, the predictive power of the model is tested in a flow cell containing a series of symmetric sudden expansions and contractions. Thrombi form in the low WSS area downstream of the asymmetric expansion and grow into the nearby recirculation region, and thrombus height and length largely remain within 95 % confidence intervals calculated from the in vitro data for 30 min of blood flow. After 30 min, predicted thrombus height and length are 0.94 and 4.32 (normalized by the 2.5 mm step height). Importantly, the model also correctly predicts locations of thrombus deposition observed in the in vitro flow cell of expansions and contractions. As the simulation results, which rely on a greatly reduced model of the thrombotic network, are still able to capture the macroscopic behavior of the full network, the model shows promise for timely predictions of device-induced thrombosis toward optimizing and expediting the device development process.
Subject(s)
Key words
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Thrombosis / Heart-Assist Devices / Models, Cardiovascular Type of study: Prognostic_studies / Risk_factors_studies Limits: Animals Language: En Journal: Biomech Model Mechanobiol Journal subject: ENGENHARIA BIOMEDICA Year: 2016 Document type: Article Affiliation country: United States
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Thrombosis / Heart-Assist Devices / Models, Cardiovascular Type of study: Prognostic_studies / Risk_factors_studies Limits: Animals Language: En Journal: Biomech Model Mechanobiol Journal subject: ENGENHARIA BIOMEDICA Year: 2016 Document type: Article Affiliation country: United States