Your browser doesn't support javascript.
loading
Effect of CPAP Withdrawal on BP in OSA: Data from Three Randomized Controlled Trials.
Schwarz, Esther I; Schlatzer, Christian; Rossi, Valentina A; Stradling, John R; Kohler, Malcolm.
Affiliation
  • Schwarz EI; Sleep Disorders Center and Pulmonary Division, University Hospital of Zurich, Zurich, Switzerland.
  • Schlatzer C; Sleep Disorders Center and Pulmonary Division, University Hospital of Zurich, Zurich, Switzerland.
  • Rossi VA; Sleep Disorders Center and Pulmonary Division, University Hospital of Zurich, Zurich, Switzerland.
  • Stradling JR; National Institute for Health Research, Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust and University of Oxford, Oxford, England.
  • Kohler M; Sleep Disorders Center and Pulmonary Division, University Hospital of Zurich, Zurich, Switzerland; Center for Integrative Human Physiology, University of Zurich, Zurich, Switzerland. Electronic address: malcolm.kohler@usz.ch.
Chest ; 150(6): 1202-1210, 2016 Dec.
Article in En | MEDLINE | ID: mdl-27452767
BACKGROUND: Based on meta-analyses, the BP-lowering effect of CPAP therapy in patients with OSA is reported to be approximately 2 to 3 mm Hg. This figure is derived from heterogeneous trials, which are often limited by poor CPAP adherence, and thus the treatment effect may possibly be underestimated. We analyzed morning BP data from three randomized controlled CPAP withdrawal trials, which included only patients with optimal CPAP compliance. METHODS: Within the three trials, 149 patients with OSA who were receiving CPAP were randomized to continue therapeutic CPAP (n = 65) or to withdraw CPAP (n = 84) for 2 weeks. Morning BP was measured at home before and after sleep studies in the hospital. RESULTS: CPAP withdrawal was associated with a return of OSA (apnea-hypopnea index [AHI] at a baseline of 2.8/h and at follow-up of 33.2/h). Office systolic BP (SBP) increased in the CPAP withdrawal group compared with the CPAP continuation group by +5.4 mm Hg (95% CI, 1.8-8.9 mm Hg; P = .003) and in the home SBP group by +9.0 mm Hg (95% CI, 5.7-12.3 mm Hg; P < .001). Office diastolic BP (DBP) increased by +5.0 mm Hg (95% CI, 2.7-7.3 mm Hg; P < .001), and home DBP increased by +7.8 mm Hg (95% CI, 5.6-10.4 mm Hg; P < .001). AHI, baseline home SBP, use of statin drugs, sex, and the number of antihypertensive drugs prescribed were all independently associated with SBP change in multivariate analysis, controlling for age, BMI, smoking status, diabetes, and sleepiness. CONCLUSIONS: CPAP withdrawal results in a clinically relevant increase in BP, which is considerably higher than in conventional CPAP trials; it is also underestimated when office BP is used. Greater OSA severity is associated with a higher BP rise in response to CPAP withdrawal. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01332175 and NCT01797653) URL: www.clinicaltrials.gov and ISRCTN registry (ISRCTN 93153804) URL: http://www.isrctn.com/.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Pressure / Sleep Apnea, Obstructive / Continuous Positive Airway Pressure Type of study: Clinical_trials / Systematic_reviews Limits: Female / Humans / Male / Middle aged Language: En Journal: Chest Year: 2016 Document type: Article Affiliation country: Switzerland Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Pressure / Sleep Apnea, Obstructive / Continuous Positive Airway Pressure Type of study: Clinical_trials / Systematic_reviews Limits: Female / Humans / Male / Middle aged Language: En Journal: Chest Year: 2016 Document type: Article Affiliation country: Switzerland Country of publication: United States