Your browser doesn't support javascript.
loading
Intra-Rater Reliability and Minimal Detectable Change of Vertical Ground Reaction Force Measurement during Gait and Half-Squat Tasks on Healthy Male Adults.
Fairus, Fariza Zainudin; Joseph, Leonard Henry; Omar, Baharudin; Ahmad, Johan; Sulaiman, Riza.
Affiliation
  • Fairus FZ; School of Rehabilitation Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, 50300 Kuala Lumpur, Malaysia.
  • Joseph LH; School of Rehabilitation Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, 50300 Kuala Lumpur, Malaysia.
  • Omar B; Department of Biomedical Sciences, Faculty of Allied Health Sciences, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, 50300 Kuala Lumpur, Malaysia.
  • Ahmad J; Department of Orthopedics and Traumatology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Ya'acob Latif, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, Malaysia.
  • Sulaiman R; Institute of Visual Informatics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia.
Malays J Med Sci ; 23(2): 21-7, 2016 Mar.
Article in En | MEDLINE | ID: mdl-27547111
BACKGROUND: The understanding of vertical ground reaction force (VGRF) during walking and half-squatting is necessary and commonly utilised during the rehabilitation period. The purpose of this study was to establish measurement reproducibility of VGRF that reports the minimal detectable changes (MDC) during walking and half-squatting activity among healthy male adults. METHODS: 14 male adults of average age, 24.88 (5.24) years old, were enlisted in this study. The VGRF was assessed using the force plates which were embedded into a customised walking platform. Participants were required to carry out three trials of gait and half-squat. Each participant completed the two measurements within a day, approximately four hours apart. RESULTS: Measurements of VGRF between sessions presented an excellent VGRF data for walking (ICC Left = 0.88, ICC Right = 0.89). High reliability of VGRF was also noted during the half-squat activity (ICC Left = 0.95, ICC Right = 0.90). The standard errors of measurement (SEM) of VGRF during the walking and half-squat activity are less than 8.35 Nm/kg and 4.67 Nm/kg for the gait and half-squat task respectively. CONCLUSION: The equipment set-up and measurement procedure used to quantify VGRF during walking and half-squatting among healthy males displayed excellent reliability. Researcher should consider using this method to measure the VGRF during functional performance assessment.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Malays J Med Sci Year: 2016 Document type: Article Affiliation country: Malaysia Country of publication: Malaysia

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Malays J Med Sci Year: 2016 Document type: Article Affiliation country: Malaysia Country of publication: Malaysia