Baseline impedance measured during high-resolution esophageal impedance manometry reliably discriminates GERD patients.
Ravi, K; Geno, D M; Vela, M F; Crowell, M D; Katzka, D A.
Affiliation
  • Ravi K; Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA.
  • Geno DM; Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA.
  • Vela MF; Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA.
  • Crowell MD; Department of Gastroenterology and Hepatology, Mayo Clinic, Scottsdale, AZ, USA.
  • Katzka DA; Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA.
Article in En | MEDLINE | ID: mdl-27778419
ABSTRACT

BACKGROUND:

Baseline impedance measured with ambulatory impedance pH monitoring (MII-pH) and a mucosal impedance catheter detects gastroesophageal reflux disease (GERD). However, these tools are limited by cost or patient tolerance. We investigated whether baseline impedance measured during high-resolution impedance manometry (HRIM) distinguishes GERD patients from controls.

METHODS:

Consecutive patients with clinical HRIM and MII-pH testing were identified. Gastroesophageal reflux disease was defined by esophageal pH <4 for ≥5% of both the supine and total study time, whereas controls had an esophageal pH <4 for ≤3% of the study performed off PPI. Baseline impedance was measured over 15 seconds during the landmark period of HRIM and over three 10 minute intervals during the overnight period of MII-pH. KEY

RESULTS:

Among 29 GERD patients and 26 controls, GERD patients had a mean esophageal acid exposure time of 22.7% compared to 1.2% in controls (P<.0001). Mean baseline impedance during HRIM was lower in GERD (1061 Ω) than controls (2814 Ω) (P<.0001). Baseline mucosal impedance measured during HRIM and MII-pH correlated (r=0.59, P<.0001). High-resolution esophageal manometry baseline impedance had high diagnostic accuracy for GERD, with an area under the curve (AUC) of 0.931 on receiver operating characteristics (ROC) analysis. A HRIM baseline impedance threshold of 1582 Ω had a sensitivity of 86.2% and specificity of 88.5% for GERD, with a positive predictive value of 89.3% and negative predictive value of 85.2%. CONCLUSIONS & INFERENCES Baseline impedance measured during HRIM can reliably discriminate GERD patients with at least moderate esophageal acid exposure from controls. This diagnostic tool may represent an accurate, cost-effective, and less invasive test for GERD.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Gastroesophageal Reflux / Esophageal pH Monitoring / Manometry Type of study: Prognostic_studies Limits: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Neurogastroenterol Motil Journal subject: GASTROENTEROLOGIA / NEUROLOGIA Year: 2017 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Gastroesophageal Reflux / Esophageal pH Monitoring / Manometry Type of study: Prognostic_studies Limits: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Neurogastroenterol Motil Journal subject: GASTROENTEROLOGIA / NEUROLOGIA Year: 2017 Document type: Article Affiliation country: United States