Your browser doesn't support javascript.
loading
Performance of the Real-Q EBV Quantification Kit for Epstein-Barr Virus DNA Quantification in Whole Blood.
Huh, Hee Jae; Park, Jong Eun; Kim, Ji Youn; Yun, Sun Ae; Lee, Myoung Keun; Lee, Nam Yong; Kim, Jong Won; Ki, Chang Seok.
Affiliation
  • Huh HJ; Department of Laboratory Medicine and Genetics, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea.
  • Park JE; Department of Laboratory Medicine and Genetics, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea.
  • Kim JY; Center for Clinical Medicine, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea.
  • Yun SA; Center for Clinical Medicine, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea.
  • Lee MK; Department of Laboratory Medicine and Genetics, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea.
  • Lee NY; Department of Laboratory Medicine and Genetics, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea.
  • Kim JW; Department of Laboratory Medicine and Genetics, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea.
  • Ki CS; Department of Laboratory Medicine and Genetics, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea. changski@skku.edu.
Ann Lab Med ; 37(2): 147-150, 2017 Mar.
Article in En | MEDLINE | ID: mdl-28029001
There has been increasing interest in standardized and quantitative Epstein-Barr virus (EBV) DNA testing for the management of EBV disease. We evaluated the performance of the Real-Q EBV Quantification Kit (BioSewoom, Korea) in whole blood (WB). Nucleic acid extraction and real-time PCR were performed by using the MagNA Pure 96 (Roche Diagnostics, Germany) and 7500 Fast real-time PCR system (Applied Biosystems, USA), respectively. Assay sensitivity, linearity, and conversion factor were determined by using the World Health Organization international standard diluted in EBV-negative WB. We used 81 WB clinical specimens to compare performance of the Real-Q EBV Quantification Kit and artus EBV RG PCR Kit (Qiagen, Germany). The limit of detection (LOD) and limit of quantification (LOQ) for the Real-Q kit were 453 and 750 IU/mL, respectively. The conversion factor from EBV genomic copies to IU was 0.62. The linear range of the assay was from 750 to 106 IU/mL. Viral load values measured with the Real-Q assay were on average 0.54 log10 copies/mL higher than those measured with the artus assay. The Real-Q assay offered good analytical performance for EBV DNA quantification in WB.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: DNA, Viral / Herpesvirus 4, Human Type of study: Diagnostic_studies / Evaluation_studies Limits: Humans Language: En Journal: Ann Lab Med Year: 2017 Document type: Article Country of publication: Korea (South)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: DNA, Viral / Herpesvirus 4, Human Type of study: Diagnostic_studies / Evaluation_studies Limits: Humans Language: En Journal: Ann Lab Med Year: 2017 Document type: Article Country of publication: Korea (South)