Five-year experience with immediate extubation after arterial switch operations for transposition of great arteries.
Eur J Cardiothorac Surg
; 51(4): 728-734, 2017 04 01.
Article
in En
| MEDLINE
| ID: mdl-28199509
Objectives: We sought to identify preoperative, intraoperative and anatomical factors associated with immediate extubation (IE) after arterial switch operation for d-transposition of great arteries (dTGA). Methods: This was a single-centre retrospective study performed from 1 January 2010 to 30 June 2015. IE was defined as successful extubation in the operating room (OR). Univariate/bivariate regression of preoperative, intraoperative and anatomical variables was used to determine associations with IE. Results: Of 32 patients in the dTGA spectrum (age at operation 6 days), 18 (56%) underwent IE. Twelve (71%) of the 17 patients with an intact ventricular septum and 6 (43%) of the 14 patients with ventricular septal defect (VSD) underwent IE, whereas none of the patients with double outlet right ventricle or aortic arch obstruction ( n = 4) did. Patients who had cardiopulmonary bypass time (CPB) >173 min ( P = 0.01), lowest temperature on CPB (T min) ≤ 30.4°C ( P = 0.04) and aortic cross-clamp time >86 min ( P = 0.04) were more likely to be left intubated at the end of the procedure. There was no significant difference in patient's chronological age, gestational age, post-conceptual age, weight, coronary anatomy or prevalence of VSD between those who did and did not undergo IE. There was a median increase in intensive care unit (ICU) length of stay (LOS) by 1 day (33%, P = 0.03) and ICU costs by $12 338 (15%, P = 0.06) in non-IE patients. The OR turnover time ( P = 0.09) and reintubation rate ( P = 1) at 24 h post-extubation did not differ between those who did and did not have IE. There was no myocardial dysfunction evident on predismissal echocardiography in either group. Conclusions: In this cohort of infants, post repair for TGA, 56% were extubated immediately in the OR. Greater CPB and cross-clamp times and T min ≤ 30.4°C were associated with a lesser likelihood of IE. IE was associated with shorter ICU length of stay.
Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Transposition of Great Vessels
/
Airway Extubation
/
Arterial Switch Operation
Type of study:
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limits:
Humans
/
Newborn
Language:
En
Journal:
Eur J Cardiothorac Surg
Journal subject:
CARDIOLOGIA
Year:
2017
Document type:
Article
Affiliation country:
United States
Country of publication:
Germany