Your browser doesn't support javascript.
loading
Impact of a Newly Developed Short Double-Balloon Enteroscope on Stent Placement in Patients with Surgically Altered Anatomies.
Tsutsumi, Koichiro; Kato, Hironari; Okada, Hiroyuki.
Affiliation
  • Tsutsumi K; Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan.
  • Kato H; Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan.
  • Okada H; Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan.
Gut Liver ; 11(2): 306-311, 2017 Mar 15.
Article in En | MEDLINE | ID: mdl-28208009
ABSTRACT
A newly developed short double-balloon enteroscope with a working channel enlarged to a diameter of 3.2 mm is a novel innovation in stent placement for patients with surgically altered anatomies. Herein, we report three patients in whom this new scope contributed to an efficient technique and ideal treatment. In the first case, the double guidewire technique was efficient and effective for multiple stent placements. In the second case, covered self-expandable metal stent (SEMS) placement, which is the standard treatment for malignant biliary obstruction, could be performed in a technologically sound and safe manner. In the third case, SEMS placement was performed as palliative treatment for malignant afferent-loop obstruction; this procedure could be performed soundly and safely using the through-the-scope technique. The wider working channel of this new scope also facilitates a smoother accessory insertion and high suction performance, which reduces procedure time and stress on endoscopists. Furthermore, this new scope, which has advanced force transmission, adaptive bending, and a smaller turning radius, is expected to be highly successful in both diagnosis and therapy for various digestive diseases in patients with surgically altered anatomies.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Stents / Prosthesis Implantation / Endoscopes, Gastrointestinal / Digestive System Abnormalities / Double-Balloon Enteroscopy Type of study: Etiology_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Gut Liver Year: 2017 Document type: Article Affiliation country: Japan

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Stents / Prosthesis Implantation / Endoscopes, Gastrointestinal / Digestive System Abnormalities / Double-Balloon Enteroscopy Type of study: Etiology_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Gut Liver Year: 2017 Document type: Article Affiliation country: Japan