Your browser doesn't support javascript.
loading
Laser beam melting 3D printing of Ti6Al4V based porous structured dental implants: fabrication, biocompatibility analysis and photoelastic study.
Yang, Fei; Chen, Chen; Zhou, QianRong; Gong, YiMing; Li, RuiXue; Li, ChiChi; Klämpfl, Florian; Freund, Sebastian; Wu, XingWen; Sun, Yang; Li, Xiang; Schmidt, Michael; Ma, Duan; Yu, YouCheng.
Affiliation
  • Yang F; Department of Stomatology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
  • Chen C; Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Konrad-Zuse-Str. 3/5, D-91052 Erlangen, Germany.
  • Zhou Q; Erlangen Graduate School in Advanced Optical Technologies, Paul-Gordan-Str. 6, D-91052 Erlangen, Germany.
  • Gong Y; Department of Stomatology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
  • Li R; Department of Stomatology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
  • Li C; Department of Stomatology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
  • Klämpfl F; Department of Plastic Surgery, The 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, 325000, China.
  • Freund S; Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Konrad-Zuse-Str. 3/5, D-91052 Erlangen, Germany.
  • Wu X; Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Konrad-Zuse-Str. 3/5, D-91052 Erlangen, Germany.
  • Sun Y; Erlangen Graduate School in Advanced Optical Technologies, Paul-Gordan-Str. 6, D-91052 Erlangen, Germany.
  • Li X; Department of Stomatology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
  • Schmidt M; Department of Stomatology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
  • Ma D; State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China.
  • Yu Y; Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Konrad-Zuse-Str. 3/5, D-91052 Erlangen, Germany.
Sci Rep ; 7: 45360, 2017 03 28.
Article in En | MEDLINE | ID: mdl-28350007

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Titanium / Biocompatible Materials / Dental Implants Limits: Animals Language: En Journal: Sci Rep Year: 2017 Document type: Article Affiliation country: China Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Titanium / Biocompatible Materials / Dental Implants Limits: Animals Language: En Journal: Sci Rep Year: 2017 Document type: Article Affiliation country: China Country of publication: United kingdom