Your browser doesn't support javascript.
loading
Stem loop-mediated isothermal amplification test: comparative analysis with classical LAMP and PCR in detection of Entamoeba histolytica in Kenya.
Mwendwa, Fridah; Mbae, Cecilia K; Kinyua, Johnson; Mulinge, Erastus; Mburugu, Gitonga Nkanata; Njiru, Zablon K.
Affiliation
  • Mwendwa F; Institute of Tropical Medicine and Infectious Diseases, Jomo Kenyatta University of Agriculture and Technology, P.O Box 62000-0200, Nairobi, Kenya. fridahmwendwa.fm@gmail.com.
  • Mbae CK; Centre for Microbiology Research, Kenya Medical Research Institute, P.O Box 19464-00202, Nairobi, Kenya.
  • Kinyua J; Department of Biochemistry, Jomo Kenyatta University of Agriculture and Technology, P.O Box 62000-0200, Nairobi, Kenya.
  • Mulinge E; Centre for Microbiology Research, Kenya Medical Research Institute, P.O Box 19464-00202, Nairobi, Kenya.
  • Mburugu GN; Meru University of Science and Technology, P. O. Box 972-60200, Meru, Kenya.
  • Njiru ZK; Meru University of Science and Technology, P. O. Box 972-60200, Meru, Kenya.
BMC Res Notes ; 10(1): 142, 2017 Mar 31.
Article in En | MEDLINE | ID: mdl-28359328
ABSTRACT

BACKGROUND:

Entamoeba histolytica, the causative agent for amoebiasis is a considerable burden to population in the developing countries where it accounts for over 50 million infections. The tools for detection of amoebiasis are inadequate and diagnosis relies on microscopy which means a significant percent of cases remain undiagnosed. Moreover, tests formats that can be rapidly applied in rural endemic areas are not available.

METHODS:

In this study, a loop-mediated isothermal test (LAMP) based on 18S small subunit ribosomal RNA gene was designed with extra reaction accelerating primers (stem primers) and compared with the published LAMP and PCR tests in detection of E. histolytica DNA in clinical samples.

RESULTS:

The stem LAMP test indicated shorter time to results by an average 11 min and analytical sensitivity of 10-7 (~30 pg/ml) compared to the standard LAMP and PCR which showed sensitivities levels of 10-5 (~3 ng/ml) and 10-4 (~30 ng/ml) respectively using tenfold serial dilution of DNA. In the analysis of clinical specimens positive for Entamoeba spp. trophozoites and cysts using microscopy, the stem LAMP test detected E. histolytica DNA in 36/126, standard LAMP test 20/126 and PCR 17/126 cases respectively. There was 100% agreement in detection of the stem LAMP test product using fluorescence of SYTO-9 dye in real time machine, through addition of 1/10 dilution of SYBR® Green I and electrophoresis in 2% agarose gel stained with ethidium bromide.

CONCLUSION:

The stem LAMP test developed in this study indicates potential towards detection of E. histolytica.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymerase Chain Reaction / Nucleic Acid Amplification Techniques / Entamoeba histolytica / Entamoebiasis Type of study: Diagnostic_studies Limits: Child / Humans Country/Region as subject: Africa Language: En Journal: BMC Res Notes Year: 2017 Document type: Article Affiliation country: Kenya Publication country: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymerase Chain Reaction / Nucleic Acid Amplification Techniques / Entamoeba histolytica / Entamoebiasis Type of study: Diagnostic_studies Limits: Child / Humans Country/Region as subject: Africa Language: En Journal: BMC Res Notes Year: 2017 Document type: Article Affiliation country: Kenya Publication country: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM