Your browser doesn't support javascript.
loading
Therapeutic drug monitoring of mitotane: Analytical assay and patient follow-up.
Feliu, Catherine; Cazaubon, Yoann; Guillemin, Helene; Vautier, Damien; Oget, Olivier; Millart, Hervé; Gozalo, Claire; Djerada, Zoubir.
Affiliation
  • Feliu C; Department of Pharmacology, Centre Hospitalier Universitaire de Reims, Reims, France.
  • Cazaubon Y; Department of Pharmacology, Centre Hospitalier Universitaire de Reims, Reims, France.
  • Guillemin H; Department of Pharmacology, Centre Hospitalier Universitaire de Reims, Reims, France.
  • Vautier D; Department of Pharmacology, Centre Hospitalier Universitaire de Reims, Reims, France.
  • Oget O; Department of Pharmacology, Centre Hospitalier Universitaire de Reims, Reims, France.
  • Millart H; Department of Pharmacology, Centre Hospitalier Universitaire de Reims, Reims, France.
  • Gozalo C; Department of Pharmacology, Centre Hospitalier Universitaire de Reims, Reims, France.
  • Djerada Z; Department of Pharmacology, Centre Hospitalier Universitaire de Reims, Reims, France.
Biomed Chromatogr ; 31(11)2017 Nov.
Article in En | MEDLINE | ID: mdl-28432798
ABSTRACT
Adrenocortical carcinoma (ACC) is an aggressive malignancy of the adrenal gland. Mitotane (o,p'-DDD) is the most effective chemotherapy for ACC. According to the literature, mitotane plasma trough concentrations within 14-20 mg L-1 are correlated with a higher response rate with acceptable toxicity. Therapeutic drug monitoring (TDM) of mitotane is therefore recommended. The aim of this study was to propose a robust and simple method for mitotane quantification in plasma. The validation procedures were based on international guidelines. Sample preparation consisted of a single protein precipitation with methanol using 100 µL of plasma. The supernatant was submitted to liquid chromatography coupled with ultra-violet detection at 230 nm. Mitotane retention time was 7.1 min. The limit of detection was 0.1 mg L-1 and the limit of quantification was 0.78 mg L-1 . The assay demonstrated a linear range of 0.78-25 mg L-1 with correlation coefficients (r2 ) at 0.999. Inter- and intra-assay precision was <4.85%. Evaluation of accuracy showed a deviation <13.69% from target concentration at each quality control level. This method proved easy and rapid to perform mitotane TDM and required a small volume of sample. It was successfully applied to routine TDM in our laboratory.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Chromatography, High Pressure Liquid / Drug Monitoring / Mitotane Type of study: Guideline / Prognostic_studies Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Biomed Chromatogr Year: 2017 Document type: Article Affiliation country: France

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Chromatography, High Pressure Liquid / Drug Monitoring / Mitotane Type of study: Guideline / Prognostic_studies Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Biomed Chromatogr Year: 2017 Document type: Article Affiliation country: France