Your browser doesn't support javascript.
loading
Deproteinization assessment using isotopically enriched compounds to trace the coprecipitation of low-molecular-weight selenium species with proteins.
Godin, Simon; Bouzas-Ramos, Diego; Fontagné-Dicharry, Stéphanie; Bouyssière, Brice; Bueno, Maïté.
Affiliation
  • Godin S; CNRS/Univ. Pau & Pays de l'Adour, Institut des Sciences Analytiques et de Physico-Chimie pour l'Environnement et les Matériaux, LCABIE, UMR 5254, 64053 Pau, France. Electronic address: simon.godin@univ-pau.fr.
  • Bouzas-Ramos D; CNRS/Univ. Pau & Pays de l'Adour, Institut des Sciences Analytiques et de Physico-Chimie pour l'Environnement et les Matériaux, LCABIE, UMR 5254, 64053 Pau, France; Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería 8, 33006, Oviedo, Spain. Electronic address:
  • Fontagné-Dicharry S; NUMEA, INRA, Univ. Pau & Pays de l'Adour, 64310, Saint-Pée-sur-Nivelle, France. Electronic address: stephanie.fontagne-dicharry@inra.fr.
  • Bouyssière B; CNRS/Univ. Pau & Pays de l'Adour, Institut des Sciences Analytiques et de Physico-Chimie pour l'Environnement et les Matériaux, LCABIE, UMR 5254, 64053 Pau, France. Electronic address: brice.bouyssiere@univ-pau.fr.
  • Bueno M; CNRS/Univ. Pau & Pays de l'Adour, Institut des Sciences Analytiques et de Physico-Chimie pour l'Environnement et les Matériaux, LCABIE, UMR 5254, 64053 Pau, France. Electronic address: maite.bueno@univ-pau.fr.
Anal Biochem ; 530: 9-16, 2017 08 01.
Article in En | MEDLINE | ID: mdl-28476531
ABSTRACT
Studies have shown that information related to the presence of low-molecular-weight metabolites is frequently lost after deproteinization of complex matrices, such as blood and plasma, during sample preparation. Therefore, the effect of several deproteinization reagents on low-molecular-weight selenium species has been compared by species-specific isotope labeling. Two isotopically enriched selenium tracers were used to mimic models of small inorganic anionic (77Se-selenite) and organic zwitterionic (76Se-selenomethionine) species. The results presented here show that the use of a methanol-acetonitrile-acetone (111 v/v/v) mixture provided approximately two times less tracer loss from plasma samples in comparison with the classic procedure using acetonitrile, which may not be optimal as it leads to important losses of low-molecular-weight selenium species. In addition, the possible interactions between selenium tracers and proteins were investigated, revealing that both coprecipitation phenomena and association with proteins were potentially responsible for selenite tracer losses during protein precipitation in blood samples. However, coprecipitation phenomena were found to be fully responsible for losses of both tracers observed in plasma samples and of the selenomethionine tracer in blood samples. This successfully applied strategy is anticipated to be useful for more extensive future studies in selenometabolomics.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Plasma / Radioactive Tracers / Selenium / Selenomethionine / Selenium Radioisotopes / Blood Proteins Language: En Journal: Anal Biochem Year: 2017 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Plasma / Radioactive Tracers / Selenium / Selenomethionine / Selenium Radioisotopes / Blood Proteins Language: En Journal: Anal Biochem Year: 2017 Document type: Article