Your browser doesn't support javascript.
loading
The bias of a two-dimensional view: comparing two-dimensional and three-dimensional mesophyll surface area estimates using noninvasive imaging.
Théroux-Rancourt, Guillaume; Earles, J Mason; Gilbert, Matthew E; Zwieniecki, Maciej A; Boyce, C Kevin; McElrone, Andrew J; Brodersen, Craig R.
Affiliation
  • Théroux-Rancourt G; Department of Plant Sciences, University of California Davis, Davis, CA, 95616, USA.
  • Earles JM; School of Forestry & Environmental Studies, Yale University, New Haven, CT, 06511, USA.
  • Gilbert ME; Department of Plant Sciences, University of California Davis, Davis, CA, 95616, USA.
  • Zwieniecki MA; Department of Plant Sciences, University of California Davis, Davis, CA, 95616, USA.
  • Boyce CK; Department of Geological Sciences, Stanford University, Stanford, CA, 94305, USA.
  • McElrone AJ; USDA-Agricultural Research Service, Davis, CA, 95616, USA.
  • Brodersen CR; Deparment of Viticulture and Enology, University of California, Davis, CA, 95616, USA.
New Phytol ; 215(4): 1609-1622, 2017 Sep.
Article in En | MEDLINE | ID: mdl-28691233
ABSTRACT
The mesophyll surface area exposed to intercellular air space per leaf area (Sm ) is closely associated with CO2 diffusion and photosynthetic rates. Sm is typically estimated from two-dimensional (2D) leaf sections and corrected for the three-dimensional (3D) geometry of mesophyll cells, leading to potential differences between the estimated and actual cell surface area. Here, we examined how 2D methods used for estimating Sm compare with 3D values obtained from high-resolution X-ray microcomputed tomography (microCT) for 23 plant species, with broad phylogenetic and anatomical coverage. Relative to 3D, uncorrected 2D Sm estimates were, on average, 15-30% lower. Two of the four 2D Sm methods typically fell within 10% of 3D values. For most species, only a few 2D slices were needed to accurately estimate Sm within 10% of the whole leaf sample median. However, leaves with reticulate vein networks required more sections because of a more heterogeneous vein coverage across slices. These results provide the first comparison of the accuracy of 2D methods in estimating the complex 3D geometry of internal leaf surfaces. Because microCT is not readily available, we provide guidance for using standard light microscopy techniques, as well as recommending standardization of reporting Sm values.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Imaging, Three-Dimensional / Bromeliaceae / Mesophyll Cells Language: En Journal: New Phytol Journal subject: BOTANICA Year: 2017 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Imaging, Three-Dimensional / Bromeliaceae / Mesophyll Cells Language: En Journal: New Phytol Journal subject: BOTANICA Year: 2017 Document type: Article Affiliation country: United States