Your browser doesn't support javascript.
loading
Evaluation of the physicochemical properties of silicone- and epoxy resin-based root canal sealers.
Camargo, Rafael Verardino de; Silva-Sousa, Yara Terezinha Corrêa; Rosa, Rodrigo Presotto Ferreira da; Mazzi-Chaves, Jardel Francisco; Lopes, Fabiane Carneiro; Steier, Liviu; Sousa-Neto, Manoel Damião.
Affiliation
  • Camargo RV; Universidade de São Paulo - USP, School of Dentistry of Ribeirão Preto, Department of Restorative Dentistry, Ribeirão Preto, SP, Brazil.
  • Silva-Sousa YTC; Universidade de Ribeirão Preto - Unaerp, Faculty of Dentistry, Ribeirão Preto, SP, Brazil.
  • Rosa RPFD; Universidade de São Paulo - USP, School of Dentistry of Ribeirão Preto, Department of Restorative Dentistry, Ribeirão Preto, SP, Brazil.
  • Mazzi-Chaves JF; Universidade de São Paulo - USP, School of Dentistry of Ribeirão Preto, Department of Restorative Dentistry, Ribeirão Preto, SP, Brazil.
  • Lopes FC; Universidade de São Paulo - USP, School of Dentistry of Ribeirão Preto, Department of Restorative Dentistry, Ribeirão Preto, SP, Brazil.
  • Steier L; The University of Warwick, Warwick Medical School, Coventry, United Kingdom.
  • Sousa-Neto MD; Universidade de São Paulo - USP, School of Dentistry of Ribeirão Preto, Department of Restorative Dentistry, Ribeirão Preto, SP, Brazil.
Braz Oral Res ; 31: e72, 2017 Aug 21.
Article in En | MEDLINE | ID: mdl-28832718
ABSTRACT
To assess the physicochemical properties of AH Plus, GuttaFlow 2, GuttaFlow BioSeal, and MM Seal, five samples of each root canal sealer were evaluated to determine their setting time (ST), dimensional change (DC), solubility (SL), flow (FL), and radiopacity (RD) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. The distilled and deionized water obtained from the SL test were subjected to atomic absorption spectrometry to observe the presence of Ca2+, K+, and Na+ ions. Statistical analysis was performed by using one-way ANOVA and Tukey-Kramer tests (p < 0.05). The following results were obtained ST (min) (AH Plus 463.6 ± 13.22; GuttaFlow 2 24.35 ± 2.78; GuttaFlow Bioseal 17.4 ± 0.55; MM Seal 47.60 ± 4.39), DC (%) (AH Plus 0.06 ± 0.12; GuttaFlow 2 -26.06 ± 1.24; GuttaFlow Bioseal 2.10 ± 1.47; MM Seal 8.47 ± 2.41), SL (%) (AH Plus 0.41 ± 0.21; GuttaFlow 2 5.13 ± 4.11; GuttaFlow Bioseal 3.03 ± 1.05; MM Seal 0.94 ± 0.17), FL (mm) (AH Plus 36.42 ± 0.40; GuttaFlow 2 36.44 ± 0.05; GuttaFlow Bioseal 35.4 ± 0.03; MM Seal 52.75 ± 0.60), and RD (mmAl) (AH Plus 7.52 ± 1.59; GuttaFlow 2 6.85 ± 0.14; GuttaFlow Bioseal 7.02 ± 0.18; MM Seal 3.32 ± 0.90). ST, DC, SL, FL, and RD showed statistical differences among the root canal sealers (p < 0.05). As AH Plus showed the lowest DC and SL values (p < 0.05), the findings indicate that this sample is the only sealer conforming to ANSI/ADA standards.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Root Canal Filling Materials / Silicones / Dimethylpolysiloxanes / Epoxy Resins / Gutta-Percha Type of study: Evaluation_studies Language: En Journal: Braz Oral Res Journal subject: ODONTOLOGIA Year: 2017 Document type: Article Affiliation country: Brazil

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Root Canal Filling Materials / Silicones / Dimethylpolysiloxanes / Epoxy Resins / Gutta-Percha Type of study: Evaluation_studies Language: En Journal: Braz Oral Res Journal subject: ODONTOLOGIA Year: 2017 Document type: Article Affiliation country: Brazil