Your browser doesn't support javascript.
loading
Subchronic Centrifugal Mechanical Assist in an Unheparinized Calf Model.
Wagner-Mann, Colette; Curtis, Jack; Mann, Fred A; Turk, James; Demmy, Todd; Turpin, Timothy.
Affiliation
  • Wagner-Mann C; Division of Cardiotlwracic Surgery, School of Medicine, Departments of Veterinary Medicine and Surgery, University of Missouri, Columbia, Missouri, U.S.A.Pathbiology, College of Veterinary Medicine, University of Missouri, Columbia, Missouri, U.S.A.
  • Curtis J; Division of Cardiotlwracic Surgery, School of Medicine, Departments of Veterinary Medicine and Surgery, University of Missouri, Columbia, Missouri, U.S.A.Pathbiology, College of Veterinary Medicine, University of Missouri, Columbia, Missouri, U.S.A.
  • Mann FA; Division of Cardiotlwracic Surgery, School of Medicine, Departments of Veterinary Medicine and Surgery, University of Missouri, Columbia, Missouri, U.S.A.Pathbiology, College of Veterinary Medicine, University of Missouri, Columbia, Missouri, U.S.A.
  • Turk J; Division of Cardiotlwracic Surgery, School of Medicine, Departments of Veterinary Medicine and Surgery, University of Missouri, Columbia, Missouri, U.S.A.Pathbiology, College of Veterinary Medicine, University of Missouri, Columbia, Missouri, U.S.A.
  • Demmy T; Division of Cardiotlwracic Surgery, School of Medicine, Departments of Veterinary Medicine and Surgery, University of Missouri, Columbia, Missouri, U.S.A.Pathbiology, College of Veterinary Medicine, University of Missouri, Columbia, Missouri, U.S.A.
  • Turpin T; Division of Cardiotlwracic Surgery, School of Medicine, Departments of Veterinary Medicine and Surgery, University of Missouri, Columbia, Missouri, U.S.A.Pathbiology, College of Veterinary Medicine, University of Missouri, Columbia, Missouri, U.S.A.
Artif Organs ; 20(5): 666-669, 1996 May.
Article in En | MEDLINE | ID: mdl-28868725
The purpose of this study was to determine whether the major centrifugal pumps currently in use in the United States (Medtronic, BioMedicus BioPump and Carmeda-coated BioPump, Sams 3M centrifugal pump, and St. Jude Medical Lifestream) could function as left mechanical assist devices in the subchronic (72 h) unheparinized calf model. Calves were instrumented for left atrial to aorta ex vivo assist, and the pump flow was set at 3.5 ± 0.4 L/min. Two calves (Sarns 3M and St. Jude) survived 72 h of pumping without clinical complications. The other 2 calves died at 62 and 66 h (Medtronic Bio-Pump and Carmeda-coated BioPump, respectively); both had pelvic limb paralysis. The seal of the Sarns 3M pump head ruptured after approximately 36 h of pumping and required replacement. On postmortem examination, pump-associated thromboembolic lesions were detected in 3 of the 4 calves in one or more of the following organs: kidney, pancreas, abomasum, duodenum, ileum, spleen, and lumbar spinal cord. The calf with the Sarns 3M pump had no discernable lesions. Because of the clinical abnormalities and postmortem lesions in the unheparinized calf model, it was suggested that anticoagulation is necessary for conducting centrifugal mechanical assist studies in calves using presently available technology.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Artif Organs Year: 1996 Document type: Article Affiliation country: United States Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Artif Organs Year: 1996 Document type: Article Affiliation country: United States Country of publication: United States