Your browser doesn't support javascript.
loading
Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.
Favazza, Christopher P; Ferrero, Andrea; Yu, Lifeng; Leng, Shuai; McMillan, Kyle L; McCollough, Cynthia H.
Affiliation
  • Favazza CP; Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
  • Ferrero A; Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
  • Yu L; Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
  • Leng S; Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
  • McMillan KL; Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
  • McCollough CH; Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
J Med Imaging (Bellingham) ; 4(3): 031213, 2017 Jul.
Article in En | MEDLINE | ID: mdl-28983493
ABSTRACT
The use of iterative reconstruction (IR) algorithms in CT generally decreases image noise and enables dose reduction. However, the amount of dose reduction possible using IR without sacrificing diagnostic performance is difficult to assess with conventional image quality metrics. Through this investigation, achievable dose reduction using a commercially available IR algorithm without loss of low contrast spatial resolution was determined with a channelized Hotelling observer (CHO) model and used to optimize a clinical abdomen/pelvis exam protocol. A phantom containing 21 low contrast disks-three different contrast levels and seven different diameters-was imaged at different dose levels. Images were created with filtered backprojection (FBP) and IR. The CHO was tasked with detecting the low contrast disks. CHO performance indicated dose could be reduced by 22% to 25% without compromising low contrast detectability (as compared to full-dose FBP images) whereas 50% or more dose reduction significantly reduced detection performance. Importantly, default settings for the scanner and protocol investigated reduced dose by upward of 75%. Subsequently, CHO-based protocol changes to the default protocol yielded images of higher quality and doses more consistent with values from a larger, dose-optimized scanner fleet. CHO assessment provided objective data to successfully optimize a clinical CT acquisition protocol.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Guideline Language: En Journal: J Med Imaging (Bellingham) Year: 2017 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Guideline Language: En Journal: J Med Imaging (Bellingham) Year: 2017 Document type: Article Affiliation country: United States