Your browser doesn't support javascript.
loading
Small, mobile, persistent: Trifluoroacetate in the water cycle - Overlooked sources, pathways, and consequences for drinking water supply.
Scheurer, Marco; Nödler, Karsten; Freeling, Finnian; Janda, Joachim; Happel, Oliver; Riegel, Marcel; Müller, Uwe; Storck, Florian Rüdiger; Fleig, Michael; Lange, Frank Thomas; Brunsch, Andrea; Brauch, Heinz-Jürgen.
Affiliation
  • Scheurer M; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany. Electronic address: marco.scheurer@tzw.de.
  • Nödler K; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany.
  • Freeling F; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany.
  • Janda J; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany.
  • Happel O; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany.
  • Riegel M; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany.
  • Müller U; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany.
  • Storck FR; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany.
  • Fleig M; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany.
  • Lange FT; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany.
  • Brunsch A; Erftverband, Am Erftverband 6, Bergheim 50126, Germany.
  • Brauch HJ; TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, Karlsruhe 76139, Germany.
Water Res ; 126: 460-471, 2017 12 01.
Article in En | MEDLINE | ID: mdl-28992593
ABSTRACT
Elevated concentrations of trifluoroacetate (TFA) of more than 100 µg/L in a major German river led to the occurrence of more than 20 µg/L TFA in bank filtration based tap waters. Several spatially resolved monitoring programs were conducted and discharges from an industrial company were identified as the point source of TFA contamination. Treatment options for TFA removal were investigated at full-scale waterworks and in laboratory batch tests. Commonly applied techniques like ozonation or granulated activated carbon filtration are inappropriate for TFA removal, whereas TFA was partly removed by ion exchange and completely retained by reverse osmosis. Further investigations identified wastewater treatment plants (WWTPs) as additional TFA dischargers into the aquatic environment. TFA was neither removed by biological wastewater treatment, nor by a retention soil filter used for the treatment of combined sewer overflows. WWTP influents can even bear a TFA formation potential, when appropriate CF3-containing precursors are present. Biological degradation and ozonation batch experiments with chemicals of different classes (flurtamone, fluopyram, tembotrione, flufenacet, fluoxetine, sitagliptine and 42 fluorotelomer sulfonate) proved that there are yet overlooked sources and pathways of TFA, which need to be addressed in the future.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Water Pollutants, Chemical / Trifluoroacetic Acid / Water Purification Type of study: Evaluation_studies Language: En Journal: Water Res Year: 2017 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Water Pollutants, Chemical / Trifluoroacetic Acid / Water Purification Type of study: Evaluation_studies Language: En Journal: Water Res Year: 2017 Document type: Article