Your browser doesn't support javascript.
loading
Influence of heart rate on coronary calcium scores: a multi-manufacturer phantom study.
van der Werf, N R; Willemink, M J; Willems, T P; Vliegenthart, R; Greuter, M J W; Leiner, T.
Affiliation
  • van der Werf NR; Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands. n.r.vanderwerf@umcutrecht.nl.
  • Willemink MJ; Department of Radiology, Center for Medical Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands. n.r.vanderwerf@umcutrecht.nl.
  • Willems TP; Department of Clinical Physics, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3318 AT, Dordrecht, The Netherlands. n.r.vanderwerf@umcutrecht.nl.
  • Vliegenthart R; Department of Radiology, University Medical Center Utrecht, E01.132, PO Box 85500, 3508 GA, Utrecht, The Netherlands. n.r.vanderwerf@umcutrecht.nl.
  • Greuter MJW; Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
  • Leiner T; Department of Radiology, Center for Medical Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.
Int J Cardiovasc Imaging ; 34(6): 959-966, 2018 Jun.
Article in En | MEDLINE | ID: mdl-29285727
ABSTRACT
To evaluate the influence of heart rate on coronary calcium scores (CCS) using a dynamic phantom on four high-end computed tomography (CT) systems from different manufacturers. Artificial coronary arteries were moved in an anthropomorphic chest phantom at linear velocities, corresponding to < 60, 60-75 and > 75 beats per minute (bpm). Data was acquired with routinely used clinical protocols for CCS on four high-end CT systems (CT1-CT4). CCS, quantified as Agatston and mass scores were compared to reference scores at < 60 bpm. Influence of heart rate was assessed for each system with the cardiac motion susceptibility (CMS) Index. At increased heart rates (> 75 bpm), Agatston scores of the low mass calcification were similar to the reference score, while Agatston scores of the medium and high mass calcification increased significantly up to 50% for all CT systems. Threefold CMS increases at > 75 bpm in comparison with < 60 bpm were shown. For medium and high mass calcifications, significant differences in CMS between CT systems were found. Heart rate substantially influences CCS for high-end CT systems of four major manufacturers, but CT systems differ in motion susceptibility. Follow-up CCS CT scans should be acquired on the same CT system and protocol, and preferably with comparable heart rates.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Coronary Artery Disease / Coronary Angiography / Phantoms, Imaging / Vascular Calcification / Computed Tomography Angiography / Heart Rate Type of study: Guideline / Prognostic_studies Limits: Humans Language: En Journal: Int J Cardiovasc Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2018 Document type: Article Affiliation country: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Coronary Artery Disease / Coronary Angiography / Phantoms, Imaging / Vascular Calcification / Computed Tomography Angiography / Heart Rate Type of study: Guideline / Prognostic_studies Limits: Humans Language: En Journal: Int J Cardiovasc Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2018 Document type: Article Affiliation country: Netherlands