Valve-in-valve transcatheter aortic valve implantation with CoreValve/Evolut R© for degenerated small versus bigger bioprostheses.
Scholtz, Smita; Piper, Cornelia; Horstkotte, Dieter; Gummert, Jan; Ensminger, Stephan M; Börgermann, Jochen; Scholtz, Werner.
Affiliation
  • Scholtz S; Clinic for Cardiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
  • Piper C; Clinic for Cardiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
  • Horstkotte D; Clinic for Cardiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
  • Gummert J; Clinic for Thoracic and Cardiovascular Surgery, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
  • Ensminger SM; Clinic for Thoracic and Cardiovascular Surgery, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
  • Börgermann J; Clinic for Thoracic and Cardiovascular Surgery, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
  • Scholtz W; Clinic for Cardiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
J Interv Cardiol ; 31(3): 384-390, 2018 Jun.
Article in En | MEDLINE | ID: mdl-29490430
ABSTRACT

OBJECTIVES:

We present our single center experience with Medtronic CoreValve and Evolut R regarding procedural outcome and 3 years follow-up in patients with degenerated bioprostheses.

METHODS:

From 1645 patients who underwent transfemoral TAVI at our institution between February 2009 and December 2016, 37 patients with degenerated bioprosthesis were treated with Medtronic CoreValve/Evolut R. All data concerning baseline characteristic, procedural outcomes and follow-up were entered into a dedicated database.

RESULTS:

Mean age was 83.9 ± 4.4 years and patients showed an average logistic EuroSCORE of 33.2 ± 16.7%. Successful ViV deployment was achieved in all cases, a permanent pacemaker was implanted in 16.2%, no periinterventional stroke and no coronary obstruction occurred. Mortality at 30 days was 2.7%, at 1-year follow-up 5.7% and at three years 13.5%. Depending on bioprosthesis size <23 mm versus ≥23 mm echocardiographic mean gradients post implantation were significantly higher in the smaller bioprostheses, 22.8 mmHg ± 9.4 mmHg versus 15.1 ± 7.1, P = 0.013.

CONCLUSION:

ViV-TAVI with CoreValve/R is demonstrated to be safe and effective in terms of no coronary obstruction and very low mortality up to 3 years despite slightly higher mean transprosthetic gradients especially in very small bioprostheses.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve Stenosis / Bioprosthesis / Heart Valve Prosthesis / Transcatheter Aortic Valve Replacement Type of study: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male Language: En Journal: J Interv Cardiol Journal subject: CARDIOLOGIA Year: 2018 Document type: Article Affiliation country: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve Stenosis / Bioprosthesis / Heart Valve Prosthesis / Transcatheter Aortic Valve Replacement Type of study: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male Language: En Journal: J Interv Cardiol Journal subject: CARDIOLOGIA Year: 2018 Document type: Article Affiliation country: Germany