Your browser doesn't support javascript.
loading
Simultaneous determination of 20(S)-protopanaxadiol and its three metabolites in rat plasma by LC-MS/MS: application to their pharmacokinetic studies.
Li, Jin-Qi; Wang, Jia-Feng; Li, Jie; Zhang, Shu-Han; He, Dan; Tong, Rong-Sheng; She, Shu-Ya.
Affiliation
  • Li JQ; Sichuan Academy of Medical Science and Sichuan Provincial People's Hospital, Chengdu, China.
  • Wang JF; School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
  • Li J; Sichuan Key Laboratory for Individualized Drug Therapy, Chengdu, China.
  • Zhang SH; School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
  • He D; School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
  • Tong RS; School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
  • She SY; School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
Biomed Chromatogr ; 32(8): e4252, 2018 Aug.
Article in En | MEDLINE | ID: mdl-29607527
ABSTRACT
The aim of this study was to develop an LC-MS/MS method for simultaneous determination of 20(S) protopanaxadiol (PPD) and its three metabolites, PPD-glucuronide (M1), (20S,24S)-epoxy-dammarane-3,12,25-triol (M2) and (20S,24R)-epoxydammarane-3,12,25-triol (M3), in rat plasma. Precipitation with acetonitrile was employed for sample preparation and chromatographic separations were achieved on a C18 column. The sample was detected using triple quadrupole tandem mass spectrometer with selected reaction monitoring mode. The monitored precursor-to-product ion transitions were m/z 459.4 → 375.3 for PPD, m/z 635.4 → 113.0 for M1, m/z 477.4 → 441.4 for M2 and M3 and m/z 475.4 → 391.3 for IS. The developed assay was validated according to the guidelines of the US Food and Drug Administration. The calibration curves showed good linearity over the tested concentration ranges (r > 0.9993), with the LLOQ being 1 ng/mL for all analytes. The intra- and inter-day precisions (RSD) were < 9.51% while the accuracy (RE) ranged from -8.91 to 12.84%. The extraction recovery was >80% and no obvious matrix effect was detected. The analytes were stable in rat plasma with the RE ranging from -12.34 to 9.77%. The validated assay has been successfully applied to the pharmacokinetic study of PPD as well as its metabolites in rat plasma. According to the pharmacokinetic parameters, the in vivo exposures of M1, M2 and M3 were 11.91, 47.95 and 22.62% of that of PPD, respectively.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sapogenins / Chromatography, Liquid / Tandem Mass Spectrometry Type of study: Prognostic_studies Limits: Animals Language: En Journal: Biomed Chromatogr Year: 2018 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sapogenins / Chromatography, Liquid / Tandem Mass Spectrometry Type of study: Prognostic_studies Limits: Animals Language: En Journal: Biomed Chromatogr Year: 2018 Document type: Article Affiliation country: China