Your browser doesn't support javascript.
loading
Evaluation of low-intensity anti-coagulation with a fully magnetically levitated centrifugal-flow circulatory pump-the MAGENTUM 1 study.
Netuka, Ivan; Ivák, Peter; Tucanová, Zuzana; Gregor, Stanislav; Szárszoi, Ondrej; Sood, Poornima; Crandall, Daniel; Rimsans, Jessica; Connors, Jean Marie; Mehra, Mandeep R.
Affiliation
  • Netuka I; Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic. Electronic address: ivan.netuka@ikem.cz.
  • Ivák P; Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic; Third Faculty of Medicine, Charles University, Prague, Czech Republic.
  • Tucanová Z; Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
  • Gregor S; Department of Pharmacy, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
  • Szárszoi O; Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
  • Sood P; Global Clinical, Heart Failure, Abbott, Burlington, Massachusetts, USA.
  • Crandall D; Global Clinical, Heart Failure, Abbott, Burlington, Massachusetts, USA.
  • Rimsans J; Department of Pharmacy, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Connors JM; Division of Hematology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Mehra MR; Heart and Vascular Center, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
J Heart Lung Transplant ; 37(5): 579-586, 2018 05.
Article in En | MEDLINE | ID: mdl-29655662
ABSTRACT

BACKGROUND:

The HeartMate 3 left ventricular assist system is engineered to avoid pump thrombosis, yet bleeding complications persist. We investigated the safety of low-intensity anti-coagulation in patients with the HeartMate 3.

METHODS:

The Minimal AnticoaGulation EvaluatioNTo aUgment heMocompatibility (MAGENTUM 1) pilot study is a prospective, single-arm study of low-intensity warfarin anti-coagulation in patients implanted with the HeartMate 3 pump. After standard warfarin anti-coagulation (international normalized ratio [INR] 2.0 to 3.0) and aspirin for 6 weeks post-implant, patients were transitioned to a lower INR target range of 1.5 to 1.9. The primary end-point was a composite of survival free of pump thrombosis, disabling stroke (modified Rankin score [MRS] >3), or major bleeding (excluding peri-operative bleeding) with at least 6-month post-implant follow-up. Time in therapeutic range (TTR) was measured to assess anti-coagulation target efficacy using the Rosendaal method. A safety algorithm to monitor for signs of pump thrombosis was developed and implemented.

RESULTS:

We enrolled 15 patients (mean age 57.3 ± 13.3 years), 13 men with advanced heart failure (67% with INTERMACS Profiles 2 or 3), irrespective of therapeutic goal of bridge-to-transplant or destination therapy. The primary end-point was met in 14 of 15 (93 ± 6%) patients; 1 patient developed recurrent gastrointestinal bleeding. The TTR during the reduced anti-coagulation phase (6 weeks to 6 months) was 75.3 ± 8.6%. No thrombotic events occurred.

CONCLUSIONS:

This pilot study suggests low-intensity anti-coagulation targeting an INR between 1.5 and 1.9 is achievable and safe with the HeartMate 3 cardiac pump in the short-term phase, 6-months post-implant. A large-scale trial is now warranted.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Warfarin / Heart-Assist Devices / Heart Failure / Anticoagulants Type of study: Observational_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Heart Lung Transplant Journal subject: CARDIOLOGIA / TRANSPLANTE Year: 2018 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Warfarin / Heart-Assist Devices / Heart Failure / Anticoagulants Type of study: Observational_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Heart Lung Transplant Journal subject: CARDIOLOGIA / TRANSPLANTE Year: 2018 Document type: Article