A sensitive and specific solid-phase extraction-gas chromatography-tandem mass spectrometry method for the determination of 11 haloacetic acids in aqueous samples.
Kinani, Aziz; Olivier, Jérôme; Roumiguières, Adrien; Bouchonnet, Stéphane; Kinani, Said.
Affiliation
  • Kinani A; 1 Division Recherche et Développement, Laboratoire National d'Hydraulique et Environnement (LNHE), Electricité de France (EDF), Chatou Cedex, France.
  • Olivier J; 2 LCM, CNRS-École Polytechnique, Université Paris Saclay, Palaiseau, France.
  • Roumiguières A; 1 Division Recherche et Développement, Laboratoire National d'Hydraulique et Environnement (LNHE), Electricité de France (EDF), Chatou Cedex, France.
  • Bouchonnet S; 1 Division Recherche et Développement, Laboratoire National d'Hydraulique et Environnement (LNHE), Electricité de France (EDF), Chatou Cedex, France.
  • Kinani S; 2 LCM, CNRS-École Polytechnique, Université Paris Saclay, Palaiseau, France.
Eur J Mass Spectrom (Chichester) ; 24(5): 375-383, 2018 Oct.
Article in En | MEDLINE | ID: mdl-29874933
A method for the analysis of 11 haloacetic acids in water samples has been developed. It involves enrichment of the target analytes from water samples by solid-phase extraction, derivatization to methyl esters, and gas chromatography coupled with tandem mass spectrometry determination. Gas chromatography conditions were optimized for a good separation of all haloacetic acids in a short runtime. Data were acquired in the multiple reaction monitoring mode. Six solid-phase extraction sorbents among the most widely used in environmental analysis were tested. Bakerbond SDB was retained because it has been shown to provide the best results for a large class of targeted haloacetic acids. The performances of the developed method have been assessed according to the French Standard NF T 90-210. The calibration curves for all the studied haloacetic acids had consistent slopes with r2 values > 0.99. Quantification limits between 0.01 and 0.50 µg l-1 were achieved. Satisfactory repeatability (relative standard deviation ≤ 14.3%) and intermediate precision (relative standard deviation ≤ 15.7%) were obtained. Applied to the analysis of 15 untreated water samples collected from three rivers, the method allowed the detection of five haloacetic acids including monochloroacetic acid (in 100% of the samples, <0.5-1.85 µg l-1), dichloroacetic acid (87%, <0.05-0.22 µg l-1), trichloroacetic acid (93%, <0.05-0.52 µg l-1), dibromoacetic acid (53%, <0.01-0.40 µg l-1), tribromoacetic acid (20%, <0.05-0.14 µg l-1), and bromodichloroacetic acid (6%, < 0.05 µg l-1).
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: Eur J Mass Spectrom (Chichester) Year: 2018 Document type: Article Affiliation country: France Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: Eur J Mass Spectrom (Chichester) Year: 2018 Document type: Article Affiliation country: France Country of publication: United kingdom