Your browser doesn't support javascript.
loading
Multiobjective design optimization of stent geometry with wall deformation for triangular and rectangular struts.
Putra, Narendra Kurnia; Palar, Pramudita Satria; Anzai, Hitomi; Shimoyama, Koji; Ohta, Makoto.
Affiliation
  • Putra NK; Department of Bioengineering and Robotics, Graduate School of Engineering, Tohoku University, Aramaki-Aza Aoba 6-6-4, Aoba-ku, Sendai, Miyagi, 980-8579, Japan. naren@biofluid.ifs.tohoku.ac.jp.
  • Palar PS; Institute of Fluid Science, Tohoku University, Katahira 2-1-1, Aoba-ku, Sendai, Miyagi, 980-8577, Japan.
  • Anzai H; Institute of Fluid Science, Tohoku University, Katahira 2-1-1, Aoba-ku, Sendai, Miyagi, 980-8577, Japan.
  • Shimoyama K; Institute of Fluid Science, Tohoku University, Katahira 2-1-1, Aoba-ku, Sendai, Miyagi, 980-8577, Japan.
  • Ohta M; Institute of Fluid Science, Tohoku University, Katahira 2-1-1, Aoba-ku, Sendai, Miyagi, 980-8577, Japan.
Med Biol Eng Comput ; 57(1): 15-26, 2019 Jan.
Article in En | MEDLINE | ID: mdl-29967933
The stent geometrical design (e.g., inter-strut gap, length, and strut cross-section) is responsible for stent-vessel contact problems and changes in the blood flow. These changes are crucial for causing some intravascular abnormalities such as vessel wall injury and restenosis. Therefore, structural optimization of stent design is necessary to find the optimal stent geometry design. In this study, we performed a multiobjective stent optimization for minimization of average stress and low wall shear stress ratio while considering the wall deformation in 3D flow simulations of triangular and rectangular struts. Surrogate-based optimization with Kriging method and expected hypervolume improvement (EHVI) are performed to construct the surrogate model map and find the best configuration of inter-strut gap (G) and side length (SL). In light of the results, G-SL configurations of 2.81-0.39 and 3.00-0.43 mm are suggested as the best configuration for rectangular and triangular struts, respectively. Moreover, considering the surrogate model and flow pattern conditions, we concluded that triangular struts work better to improve the intravascular hemodynamics. ᅟ Graphical abstract.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Prosthesis Design / Stress, Mechanical / Stents Language: En Journal: Med Biol Eng Comput Year: 2019 Document type: Article Affiliation country: Japan Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Prosthesis Design / Stress, Mechanical / Stents Language: En Journal: Med Biol Eng Comput Year: 2019 Document type: Article Affiliation country: Japan Country of publication: United States