Generation of customized orbital implant templates using 3-dimensional printing for orbital wall reconstruction.
Eye (Lond)
; 32(12): 1864-1870, 2018 12.
Article
in En
| MEDLINE
| ID: mdl-30154573
OBJECTIVES: To describe and evaluate a novel surgical approach to orbital wall reconstruction that uses three-dimensionally (3D) printed templates to mold a customized orbital implant. METHODS: A review was conducted of 11 consecutive patients who underwent orbital wall reconstruction using 3D-printed customized orbital implant templates. In these procedures, the orbital implant was 3D pressed during surgery and inserted into the fracture site. The outcomes of this approach were analyzed quantitatively by measuring the orbital tissue volumes within the bony orbit using computed tomography. RESULTS: All 11 orbital wall reconstructions (6 orbital floor and 5 medial wall fractures) were successful with no post operative ophthalmic complications. Statistically significant differences were found between the preoperative and post operative orbital tissue volumes for the affected orbit (24.00 ± 1.74 vs 22.31 ± 1.90 cm3; P = 0.003). There was no statistically significant difference found between the tissue volume of the contralateral unaffected orbit and the affected orbit after reconstruction (22.01 ± 1.60 cm3 vs 22.31 ± 1.90 cm3; P = 0.182). CONCLUSION: 3D-printed customized orbital implant templates can be used to press and trim conventional implantable materials with patient-specific contours and sizes for optimal orbital wall reconstruction. It is difficult to design an orbital implant that exactly matches the shape and surface of a blowout fracture site due to the unique 3D structure of the orbit. The traditional surgical method is to visually inspect the fracture site and use eye measurements to cut a two-dimensional orbital implant that corresponds to the anatomical structure of the fracture site. However, implants that do not fit the anatomical structure of a fracture site well can cause complications such as enophthalmos, diplopia and displacement of the implant.
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Orbit
/
Orbital Fractures
/
Prosthesis Design
/
Enophthalmos
/
Plastic Surgery Procedures
/
Orbital Implants
/
Printing, Three-Dimensional
Limits:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Language:
En
Journal:
Eye (Lond)
Journal subject:
OFTALMOLOGIA
Year:
2018
Document type:
Article
Country of publication:
United kingdom