Your browser doesn't support javascript.
loading
Fast ion D-alpha measurements using a bandpass-filtered system on EAST.
Zhang, J; Huang, J; Chang, J F; Wu, C R; Heidbrink, W W; Salewski, M; Madsen, B; Zhu, Y B; von Hellermann, M G; Gao, W; Xu, Z; Wan, B.
Affiliation
  • Zhang J; Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, 230031 Hefei, Anhui, China.
  • Huang J; Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, 230031 Hefei, Anhui, China.
  • Chang JF; Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, 230031 Hefei, Anhui, China.
  • Wu CR; Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, 230031 Hefei, Anhui, China.
  • Heidbrink WW; Department of Physics and Astronomy, University of California, Irvine, California 92697, USA.
  • Salewski M; Department of Physics, Technical University of Denmark, Kongens Lyngby, Denmark.
  • Madsen B; Department of Physics, Technical University of Denmark, Kongens Lyngby, Denmark.
  • Zhu YB; Department of Physics and Astronomy, University of California, Irvine, California 92697, USA.
  • von Hellermann MG; FOM Institute DIFFER, Nieuwegein 3430 BE, The Netherlands.
  • Gao W; Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, 230031 Hefei, Anhui, China.
  • Xu Z; Advanced Energy Research Center, Shenzhen University, Shenzhen 518060, People's Republic of China.
  • Wan B; Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, 230031 Hefei, Anhui, China.
Rev Sci Instrum ; 89(10): 10D121, 2018 Oct.
Article in En | MEDLINE | ID: mdl-30399922
ABSTRACT
Based on the charge exchange reaction between fast ions and a neutral beam, fast ion features can be inferred from the spectrum of Doppler-shifted Balmer-alpha light from energetic hydrogenic atoms. In order to study the interaction between instabilities and fast-ion transport, recently we extended the fast ion D-alpha (FIDA) measurements by using a combination of a bandpass filter and a photomultiplier tube (PMT) (f-FIDA). A bandpass filter selects the desired spectral band from 651 nm to 654 nm before detection by the PMT. Preliminary data from the EAST tokamak show that the active signals have been detected from reneutralized beam ions along the vertical and tangential viewing geometries. The details will be presented in this paper to primarily address the specifications and performance of f-FIDA hardware components and preliminary FIDA measurements.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Rev Sci Instrum Year: 2018 Document type: Article Affiliation country: China