Your browser doesn't support javascript.
loading
Real-time determination of enantiomeric and isomeric content using photoelectron elliptical dichroism.
Comby, A; Bloch, E; Bond, C M M; Descamps, D; Miles, J; Petit, S; Rozen, S; Greenwood, J B; Blanchet, V; Mairesse, Y.
Affiliation
  • Comby A; Université de Bordeaux - CNRS - CEA, CELIA, UMR5107, F33405, Talence, France.
  • Bloch E; Université de Bordeaux - CNRS - CEA, CELIA, UMR5107, F33405, Talence, France.
  • Bond CMM; School of Maths and Physics, Queen's University, Belfast, BT7 INN, UK.
  • Descamps D; Université de Bordeaux - CNRS - CEA, CELIA, UMR5107, F33405, Talence, France.
  • Miles J; School of Maths and Physics, Queen's University, Belfast, BT7 INN, UK.
  • Petit S; Université de Bordeaux - CNRS - CEA, CELIA, UMR5107, F33405, Talence, France.
  • Rozen S; Weizmann Institute of Science, Rehovot, 76100, Israel.
  • Greenwood JB; School of Maths and Physics, Queen's University, Belfast, BT7 INN, UK.
  • Blanchet V; Université de Bordeaux - CNRS - CEA, CELIA, UMR5107, F33405, Talence, France.
  • Mairesse Y; Université de Bordeaux - CNRS - CEA, CELIA, UMR5107, F33405, Talence, France. yann.mairesse@u-bordeaux.fr.
Nat Commun ; 9(1): 5212, 2018 12 06.
Article in En | MEDLINE | ID: mdl-30523259
ABSTRACT
The fast and accurate analysis of chiral chemical mixtures is crucial for many applications but remains challenging. Here we use elliptically-polarized femtosecond laser pulses at high repetition rates to photoionize chiral molecules. The 3D photoelectron angular distribution produced provides molecular fingerprints, showing a strong forward-backward asymmetry which depends sensitively on the molecular structure and degree of ellipticity. Continuously scanning the laser ellipticity and analyzing the evolution of the rich, multi-dimensional molecular signatures allows us to observe real-time changes in the chemical and chiral content present with unprecedented speed and accuracy. We measure the enantiomeric excess of a compound with an accuracy of 0.4% in 10 min acquisition time, and follow the evolution of a mixture with an accuracy of 5% with a temporal resolution of 3 s. This method is even able to distinguish isomers, which cannot be easily distinguished by mass-spectrometry.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Nat Commun Journal subject: BIOLOGIA / CIENCIA Year: 2018 Document type: Article Affiliation country: France

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Nat Commun Journal subject: BIOLOGIA / CIENCIA Year: 2018 Document type: Article Affiliation country: France