Your browser doesn't support javascript.
loading
Non-target data acquisition for target analysis (nDATA) of 845 pesticide residues in fruits and vegetables using UHPLC/ESI Q-Orbitrap.
Wang, Jian; Chow, Willis; Wong, Jon W; Leung, Daniel; Chang, James; Li, Mengmeng.
Affiliation
  • Wang J; Calgary Laboratory, Canadian Food Inspection Agency, 3650-36th Street N.W., Calgary, AB, T2L 2L1, Canada. jian.wang2@canada.ca.
  • Chow W; Calgary Laboratory, Canadian Food Inspection Agency, 3650-36th Street N.W., Calgary, AB, T2L 2L1, Canada.
  • Wong JW; Center for Food Safety and Applied Nutrition, US Food and Drug Administration, 5100 Paint Branch Parkway, College Park, MD, 20740, USA.
  • Leung D; Calgary Laboratory, Canadian Food Inspection Agency, 3650-36th Street N.W., Calgary, AB, T2L 2L1, Canada.
  • Chang J; ThermoFisher Scientific, 355 River Oaks Parkway, San Jose, CA, 95134, USA.
  • Li M; Henan University of Technology, Zhengzhou, 450066, Henan, China.
Anal Bioanal Chem ; 411(7): 1421-1431, 2019 Mar.
Article in En | MEDLINE | ID: mdl-30680428
ABSTRACT
A non-target data acquisition for target analysis (nDATA) workflow based on accurate mass measurements using UHPLC/ESI Q-Orbitrap full MS-data-independent acquisition and a compound database was developed to screen pesticide residues in fruit and vegetable samples. The compound database of 845 pesticides was built from dd-MS2 (data-dependent acquisition) product ion spectral data and LC retention times of individual pesticide standards. MS2 spectra of samples were acquired using multiplexing data-independent acquisition (mDIA) and variable data-independent acquisition (vDIA). Screening of pesticides in samples was based on either the retention time (± 0.5 min) and the mass accuracy (± 5 ppm) of a precursor (RTP by full MS) or the retention time (± 0.5 min) and the mass accuracy (± 5 ppm) of a precursor and its fragment ion (RTFI by full MS/DIA). In validation studies involving mDIA and vDIA analysis of 10 fruits and vegetables spiked with pesticides prior to QuEChERS sample preparation, RTP correctly found up to 765 and 796 pesticides at 10 and 100 µg/kg, respectively, whereas RTFI correctly identified up to 729 and 764 pesticides at the same respective concentrations. UHPLC/ESI Q-Orbitrap full MS/mDIA or vDIA proved to be a comprehensive detection technique and has potential for pesticide residue screening in fruits and vegetables. Graphical Abstract.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pesticides / Vegetables / Food Contamination / Chromatography, High Pressure Liquid / Spectrometry, Mass, Electrospray Ionization / Fruit Type of study: Prognostic_studies Language: En Journal: Anal Bioanal Chem Year: 2019 Document type: Article Affiliation country: Canada

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pesticides / Vegetables / Food Contamination / Chromatography, High Pressure Liquid / Spectrometry, Mass, Electrospray Ionization / Fruit Type of study: Prognostic_studies Language: En Journal: Anal Bioanal Chem Year: 2019 Document type: Article Affiliation country: Canada