Your browser doesn't support javascript.
loading
Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland.
Nowak, Marie; Sans-Merce, Marta; Lemesre, Camille; Elmiger, Raphael; Damet, Jérôme.
Affiliation
  • Nowak M; Institute for Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland; CERN, European Organization for Nuclear Research, Switzerland. Electronic address: marie.nowak@cern.ch.
  • Sans-Merce M; Institute for Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland; Department of Medical Imaging and Information Sciences, Geneva University Hospitals, Geneva, Switzerland.
  • Lemesre C; Institute for Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland.
  • Elmiger R; Federal Office of Public Health FOPH, Bern, Switzerland.
  • Damet J; Institute for Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland; CERN, European Organization for Nuclear Research, Switzerland; Department of Radiology, University of Otago, Christchurch, New Zealand.
Phys Med ; 57: 33-40, 2019 Jan.
Article in En | MEDLINE | ID: mdl-30738529
Epidemiological studies indicate that radiation damages to the eye lens occurs at lower dose values than previously considered (Worgul et al., 2007; Chodick et al., 2008; Ciraj-Bjelac et al., 2010; Rehani et al., 2011; Vano et al., 2010) [1-5]. The International Commission on Radiological Protection lowered the equivalent dose limit value for the eye lens to 20 mSv/year (ICRP, n.d.) [6]. This new limit has been incorporated into the revised Swiss legislation [7]. Prior this change, it was agreed that if the effective dose limit was respected it would implicitly imply the respect of the limit to the eye lens, for penetrating radiation. The concept had to be reviewed in the light of necessary application of the new eye lens dose limit. The new Swiss legislation proposes to use the value of Hp(0.07) measured over the protective apron to estimate the eye lens dose. This study aims to investigate the validity of this approach for medical staff during fluoroscopy guided procedures. The results show that the ratio between thorax and eye lens doses varies greatly from one medical speciality to another, but also between surgeons within the same speciality. Moreover, for a given physician, the ratio varied over the periods of surveillance. Those variations confirmed the crucial influence of external parameters related to experience, practice and workload. The surveillance method is appropriate for most of the procedures performed in the department included in this study. Nevertheless, for the particular configuration in urology, the respect of the effective dose limit measured by the routine dosimetry does not allow direct compliance with the dose limit to the eye lens, unless appropriate protective eye wear gear are worn.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Fluoroscopy / Radiation Monitoring / Occupational Exposure / Radiation Exposure / Lens, Crystalline / Medical Staff Limits: Humans Country/Region as subject: Europa Language: En Journal: Phys Med Journal subject: BIOFISICA / BIOLOGIA / MEDICINA Year: 2019 Document type: Article Country of publication: Italy

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Fluoroscopy / Radiation Monitoring / Occupational Exposure / Radiation Exposure / Lens, Crystalline / Medical Staff Limits: Humans Country/Region as subject: Europa Language: En Journal: Phys Med Journal subject: BIOFISICA / BIOLOGIA / MEDICINA Year: 2019 Document type: Article Country of publication: Italy