Augmented and Virtual Reality Instrument Tracking for Minimally Invasive Spine Surgery: A Feasibility and Accuracy Study.
Spine (Phila Pa 1976)
; 44(15): 1097-1104, 2019 Aug 01.
Article
in En
| MEDLINE
| ID: mdl-30830046
STUDY DESIGN: Cadaveric animal laboratory study. OBJECTIVE: To evaluate the feasibility and accuracy of pedicle cannulation using an augmented reality surgical navigation (ARSN) system with automatic instrument tracking, yielding feedback of instrument position in relation to deep anatomy. SUMMARY OF BACKGROUND DATA: Minimally invasive spine surgery (MISS) has the possibility of reducing surgical exposure resulting in shorter hospital stays, lower blood loss and infection rates compared with open surgery but the drawback of limiting visual feedback to the surgeon regarding deep anatomy. MISS is mainly performed using image-guided 2D fluoroscopy, thus exposing the staff to ionizing radiation. METHODS: A hybrid operating room (OR) equipped with a robotic C-arm with integrated optical cameras for augmented reality instrument navigation was used. In two pig cadavers, cone beam computed tomography (CBCT) scans were performed, a 3D model generated, and pedicle screw insertions were planned. Seventy-eight insertions were performed. Technical accuracy was assessed on post-insertion CBCTs by measuring the distance between the navigated device and the corresponding pre-planned path as well as the angular deviations. Drilling and hammering into the pedicle were also compared. Navigation time was measured. An independent reviewer assessed a simulated clinical accuracy according to Gertzbein. RESULTS: The technical accuracy was 1.7â±â1.0âmm at the bone entry point and 2.0â±â1.3âmm at the device tip. The angular deviation was 1.7â±â1.7° in the axial and 1.6â±â1.2° in the sagittal plane. Navigation time per insertion was 195â±â93âseconds. There was no difference in accuracy between hammering and drilling into the pedicle. The clinical accuracy was 97.4% to 100% depending on the screw size considered for placement. No ionizing radiation was used during navigation. CONCLUSION: ARSN with instrument tracking for MISS is feasible, accurate, and radiation-free during navigation. LEVEL OF EVIDENCE: 3.
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Spine
/
Minimally Invasive Surgical Procedures
/
Virtual Reality
Limits:
Animals
Language:
En
Journal:
Spine (Phila Pa 1976)
Year:
2019
Document type:
Article
Affiliation country:
Sweden
Country of publication:
United States