Three-dimensional paper based platform for automatically running multiple assays in a single step.
Wu, Yupan; Ren, Yukun; Han, Lianhuan; Yan, Yongda; Jiang, Hongyuan.
Affiliation
  • Wu Y; School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China.
  • Ren Y; School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China; State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China. Electronic address: rykhit@hit.edu.cn.
  • Han L; School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China.
  • Yan Y; School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China; State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China.
  • Jiang H; School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China; State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China. Electronic address: jhy_hit@sina.com.
Talanta ; 200: 177-185, 2019 Aug 01.
Article in En | MEDLINE | ID: mdl-31036171
Paper based assays are paving the way to automated, simplified, robust and cost-effective point of care testing (POCT). We propose a method for fabricating three dimensional (3D) microfluidic paper based analytical devices (µPADs) via combining thin adhesive films and paper folding, which avoids the use of cellulose powders and the complex folding sequence and simultaneously permits assays in several layers. To demonstrate the effectiveness of this approach, a 3DµPADs was designed to conduct more assays on a small footprint, allowing dual colorimetric and electrochemical detections. More importantly, we further developed a 3D platform for implementing automated and multiplexed ELISA in parallel, since ELISA, a routine and standard laboratory method, has rarely been used in practical analyses outside of the laboratory. In this configuration, complex and multistep diagnostic assays can be carried out with the addition of the sample and buffer in a simple fashion. Using Troponin I as model, the device showed a broad dynamic range of detection with a detection limit of 0.35 ng/mL. Thus, the developed platforms allow for various assays to be cost-effectively carried out on a single 3D device, showing great potential in an academic setting and point of care testing under resource-poor conditions.