Your browser doesn't support javascript.
loading
Computed tomography measurements of intraocular structures of the feline eye.
Chandrakumar, Shawn Sreenivasan; Zur Linden, Alex; Owen, Mark; Pemberton, Sarah; Pinard, Chantale L; Matsuyama, Arata; Poirier, Valerie J.
Affiliation
  • Chandrakumar SS; School of Veterinary Science, Massey University, Palmerston North, New Zealand.
  • Zur Linden A; Department of Clinical Studies, University of Guelph Ontario Veterinary College, Guelph, Ontario, Canada.
  • Owen M; School of Veterinary Science, Massey University, Palmerston North, New Zealand.
  • Pemberton S; NZ Rad Vet, Palmerston North, New Zealand.
  • Pinard CL; School of Veterinary Science, Massey University, Palmerston North, New Zealand.
  • Matsuyama A; NZ Rad Vet, Palmerston North, New Zealand.
  • Poirier VJ; Department of Clinical Studies, University of Guelph Ontario Veterinary College, Guelph, Ontario, Canada.
Vet Rec ; 184(21): 651, 2019 05 25.
Article in En | MEDLINE | ID: mdl-31040219
Diagnostic imaging of the eye can be performed using ultrasonography, MRI or CT. This study describes the CT dimensions, volumes and radiodensities of presumed normal feline intraocular structures. Nineteen adult patients were included in this retrospective study. Fourteen males and five females were included, with domestic short hair (DSH) being the predominant breed. Length, volume and radiodensity values for the lens, anterior chamber, vitreous chamber and optic nerve were calculated as well as measurements of the optic nerve width. There was no significant correlation found on linear regression analysis comparing patient's body weight with the various ocular measurements. Measurements of the lens, globe and optic nerve had significant differences (P<0.05) noted between the sexes, with males having increased values. These results may be skewed due to the large majority of male patients in the study. There was a weak correlation found between age and right eye (OD) optic nerve width, with an increase in the optic nerve width noted with increasing age. The findings of this study are a first step in establishing CT reference values for feline intraocular structure measurements.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tomography, X-Ray Computed / Eye Type of study: Observational_studies Limits: Animals Language: En Journal: Vet Rec Year: 2019 Document type: Article Affiliation country: New Zealand Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tomography, X-Ray Computed / Eye Type of study: Observational_studies Limits: Animals Language: En Journal: Vet Rec Year: 2019 Document type: Article Affiliation country: New Zealand Country of publication: United kingdom