Your browser doesn't support javascript.
loading
Development of Sound Field Audiometry System for Small Audiometric Booths and Comparison of Its Equivalence With Traditional System.
Jung, Eun Kyung; Choi, Young Mi; Kim, Eun Jung; Lee, Sungsu; Cho, Hyong-Ho.
Affiliation
  • Jung EK; Department of Otolaryngology-Head and Neck Surgery, Chonnam National University Hospital, Gwangju, Korea.
  • Choi YM; Department of Otolaryngology-Head and Neck Surgery, Chonnam National University Hospital, Gwangju, Korea.
  • Kim EJ; Department of Otolaryngology-Head and Neck Surgery, Chonnam National University Hospital, Gwangju, Korea.
  • Lee S; Department of Otolaryngology-Head and Neck Surgery, Chonnam National University Hospital, Gwangju, Korea.
  • Cho HH; Department of Otolaryngology-Head and Neck Surgery, Chonnam National University Hospital, Gwangju, Korea.
Clin Exp Otorhinolaryngol ; 13(1): 29-35, 2020 Feb.
Article in En | MEDLINE | ID: mdl-31302989
OBJECTIVES: Sound field (SF) audiometry tests are usually conducted in audiometric booths measuring greater than 2×2 m in size. However, most private ENT clinics carry about 1×1-m-sized audiometric booths, making SF audiometry testing difficult to perform. The aims of this study were to develop an SF audiometry system for use in smaller audiometric booths and compare its performance with traditional system. METHODS: The newly developed SF audiometry system can yield an SF signal at a distance of about 30 cm from the subject's ears. Its height can be adjusted according to the subject's head height. We compared SF hearing results between the new SF system and the traditional SF audiometry system in 20 adults with normal hearing (40 ears) and 24 adults with impaired hearing levels (38 ears) who wore hearing aids. Comparative parameters included warble tone audiometry threshold, a speech reception threshold (SRT), and a speech discrimination score (SDS). For statistical analysis, paired t-test was used. The equivalence of both SF systems was tested using two one-sided test (TOST) with a margin of 5 dB (normal hearing participants) and 10 dB (hearing aids wearing participants). RESULTS: Among participants with normal hearing, warble tone hearing thresholds of 0.5, 1, 2, and 4 kHz, average values of these four frequencies, and SRT were similar between the two systems (all P>0.05). Participants with hearing aids showed similar warble tone threshold and SRT (P>0.05) in both systems except for threshold of 4 kHz (P=0.033). SDS was significantly higher in the newly developed system (P<0.05). TOST results showed equivalent SF audiometry results using either system. CONCLUSION: Audiometric results of the newly developed SF audiometry system were equivalent to those of a traditional system. Therefore, the small SF audiometry system can be used at small audiometric booths present in most private ENT clinics.