Your browser doesn't support javascript.
loading
What impact can hospitalization environment produce on the ANS functioning in patients with Unresponsive Wakefulness Syndrome? - 24-hour monitoring.
Riganello, F; Napoletano, G; Cortese, M D; Arcuri, F; Solano, A; Lucca, L F; Tonin, P; Soddu, A.
Affiliation
  • Riganello F; a Reseach in Advanced Neurorehabilitation (RAN), S.Anna Institute , Crotone , Italy.
  • Napoletano G; b Department of Engineering, Modelling, Electronics and Systemistics, University of Calabria , Arcavacata di Rende (CS) , Italy.
  • Cortese MD; a Reseach in Advanced Neurorehabilitation (RAN), S.Anna Institute , Crotone , Italy.
  • Arcuri F; a Reseach in Advanced Neurorehabilitation (RAN), S.Anna Institute , Crotone , Italy.
  • Solano A; b Department of Engineering, Modelling, Electronics and Systemistics, University of Calabria , Arcavacata di Rende (CS) , Italy.
  • Lucca LF; a Reseach in Advanced Neurorehabilitation (RAN), S.Anna Institute , Crotone , Italy.
  • Tonin P; a Reseach in Advanced Neurorehabilitation (RAN), S.Anna Institute , Crotone , Italy.
  • Soddu A; c Brain and Mind Institute, Physics and Astronomy Department, Western University , London , ON , Canada.
Brain Inj ; 33(10): 1347-1353, 2019.
Article in En | MEDLINE | ID: mdl-31335209
ABSTRACT

Objectives:

Studies showed that the recovery of patients with Unresponsive Wakefulness Syndrome (UWS) is also correlated to the recovery of circadian rhythms. In this study, we observed the correlations between patients with UWS biometrical and ambient parameters.

Methods:

A dedicated monitoring system was realized to record and correlate the level of noise and luminosity with biometric Heart Rate (HR), Heart Rate Variability (HRV) and Breath Rate (BR) parameters. Eleven patients with UWS were recruited and monitored for 13 ± 7 days. Correlation of ambient and biometric parameters was analyzed by Spearman's test. Wilcoxon's test was used to compare the biometric parameters in two different moments of daily activity in the rehabilitation unit (night and day). Patients showed a moderate negative or positive correlation between biometric and ambient parameters.

Results:

Significant differences between night and morning (0.0001 < p ≤ 0.001) were found for HR, HRV and BR in seven, five and four patients, respectively, at Wilcoxon's test. HR and BR were higher during the night while HRV was lower.

Conclusion:

In patients with UWS, lower HRV and higher HR and BR during the night might be indicative of interference in sleep/wake cycles. The modifications of the environment surrounding the patient due to the unit procedures of the staff and/or some interaction modalities of the relatives may have an effect on residual endogenous mechanisms of self-regulation. However, differences between night and day in the biometrical parameters are not necessarily linked to the changes in the environment care unit.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Autonomic Nervous System / Consciousness Disorders / Environment / Hospitalization Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Brain Inj Journal subject: CEREBRO Year: 2019 Document type: Article Affiliation country: Italy

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Autonomic Nervous System / Consciousness Disorders / Environment / Hospitalization Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Brain Inj Journal subject: CEREBRO Year: 2019 Document type: Article Affiliation country: Italy