Vapor Trace Collection and Direct Ultrasensitive Detection of Nitro-Explosives by 3D Microstructured Electrodes.
Krivitsky, Vadim; Filanovsky, Boris; Bourenko, Tatiana; Granot, Eran; Praiz, Anna; Patolsky, Fernando.
Affiliation
  • Krivitsky V; School of Chemistry, the Raymond and Beverly Sackler Faculty of Exact Sciences Tel-Aviv University , Tel Aviv 69978 , Israel.
  • Filanovsky B; School of Chemistry, the Raymond and Beverly Sackler Faculty of Exact Sciences Tel-Aviv University , Tel Aviv 69978 , Israel.
  • Bourenko T; School of Chemistry, the Raymond and Beverly Sackler Faculty of Exact Sciences Tel-Aviv University , Tel Aviv 69978 , Israel.
  • Granot E; School of Chemistry, the Raymond and Beverly Sackler Faculty of Exact Sciences Tel-Aviv University , Tel Aviv 69978 , Israel.
  • Praiz A; School of Chemistry, the Raymond and Beverly Sackler Faculty of Exact Sciences Tel-Aviv University , Tel Aviv 69978 , Israel.
  • Patolsky F; School of Chemistry, the Raymond and Beverly Sackler Faculty of Exact Sciences Tel-Aviv University , Tel Aviv 69978 , Israel.
Anal Chem ; 91(22): 14375-14382, 2019 11 19.
Article in En | MEDLINE | ID: mdl-31621301
ABSTRACT
The development of a rapid, sensitive, and selective real-time detection method for explosives traces may have an enormous impact on civilian national security, military applications, and environmental monitoring. However, real-time sensing of explosives still possesses a huge analytical hurdle, rendering explosives detection an issue of burning immediacy and an enormous current challenge in terms of research and development. Even though several explosives detection methods have been established, these approaches are typically time-consuming, need relatively large equipment, demand sample preparation, require a skilled operator, and lack the capability to do high-throughput real-time detection, thus strongly constraining their mass deployment. Here, we demonstrate the use of amino-modified carbon microfiber (µCF) working electrodes for ultrasensitive, selective, and multiplex detection of nitro-based explosives. Furthermore, our sensing method works at high sampling rates by a single electrode in a single detection cycle. We hereby present the first demonstration of porous µCF electrodes used for the simultaneous collection/preconcentration of explosive molecular species through direct air sampling, followed by the electrochemical detection of the surface adsorbed electroactive species. Our chemically modified µCF electrodes allow straightforward vapor-phase detection and discrimination of multiple nitro-based explosives directly from collected air samples. Hence, our sensing approach has been shown highly effective in the ultratrace detection of nitro-based explosives, under real-world conditions.

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: Anal Chem Year: 2019 Document type: Article Affiliation country: Israel Publication country: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: Anal Chem Year: 2019 Document type: Article Affiliation country: Israel Publication country: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA