Your browser doesn't support javascript.
loading
Transmission measurement at the Bernina branch of the Aramis Beamline of SwissFEL.
Juranic, Pavle; Tiedtke, Kai; Owada, Shigeki; Tanaka, Takahiro; Jastrow, Ulf; Sorokin, Andrey; Patthey, Luc; Mankowsky, Roman; Degenhardt, Markus; Arbelo, Yunieski; Arrell, Christopher; Smedley, John; Bohon, Jen; Follath, Rolf.
Affiliation
  • Juranic P; Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Tiedtke K; DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Owada S; Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan.
  • Tanaka T; National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba 305-8568, Japan.
  • Jastrow U; DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Sorokin A; DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Patthey L; Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Mankowsky R; Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Degenhardt M; DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Arbelo Y; Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Arrell C; Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Smedley J; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • Bohon J; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • Follath R; Paul Scherrer Institut, Villigen 5232, Switzerland.
J Synchrotron Radiat ; 26(Pt 6): 2081-2085, 2019 Nov 01.
Article in En | MEDLINE | ID: mdl-31721754
ABSTRACT
The transmission of the optical components of the Bernina branch of the Aramis beamline at SwissFEL has been measured with an X-ray gas monitor from DESY and compared with a PSI gas detector upstream of the optical components. The transmission efficiencies of the Mo, Si and SiC mirror coatings of the Aramis beamline and the various other in-beam components were evaluated and compared with theoretical calculations, showing an agreement of 6% or better in all cases. The experiment has also shown the efficacy of the high-harmonic rejection mirrors at the Bernina branch of the Aramis beamline at SwissFEL, and characterized the transmission efficiency of the on-line spectrometer in the Aramis beamline. The theoretical transmission of the mirror coatings match the experimental data to within 7%. The accuracy of these measurements was checked against a radiative bolometer from a Japanese collaboration and found to agree to a level of 4% or better. Further comparisons with a diamond detector from a US-based inter-institute collaboration demonstrated a good agreement for the attenuator settings of the beamline.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Synchrotron Radiat Journal subject: RADIOLOGIA Year: 2019 Document type: Article Affiliation country: Switzerland

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Synchrotron Radiat Journal subject: RADIOLOGIA Year: 2019 Document type: Article Affiliation country: Switzerland
...