Your browser doesn't support javascript.
loading
Comparative Clinical Evaluation of NeoPlex RB-8 with Seeplex PneumoBacter ACE for Simultaneous Detection of Eight Respiratory Bacterial Pathogens.
Kim, Jeong Woo; Hong, Seong Soo; Lee, In Seop; Chi, Hyun Young; Kim, Soo-Ok; Kim, Hyeong Nyeon; Hong, Sun Pyo.
Affiliation
  • Kim JW; R&D Center, GeneMatrix Inc., Seongnam-si, Gyeonggi-do, Republic of Korea.
  • Hong SS; R&D Center, GeneMatrix Inc., Seongnam-si, Gyeonggi-do, Republic of Korea.
  • Lee IS; Samkwang Medical Laboratories, Seoul, Republic of Korea.
  • Chi HY; Samkwang Medical Laboratories, Seoul, Republic of Korea.
  • Kim SO; R&D Center, GeneMatrix Inc., Seongnam-si, Gyeonggi-do, Republic of Korea.
  • Kim HN; Samkwang Medical Laboratories, Seoul, Republic of Korea dockylekim@gmail.com sunphong@genematrix.net.
  • Hong SP; R&D Center, GeneMatrix Inc., Seongnam-si, Gyeonggi-do, Republic of Korea dockylekim@gmail.com sunphong@genematrix.net.
J Clin Microbiol ; 58(2)2020 01 28.
Article in En | MEDLINE | ID: mdl-31748320
There are several convenient and accurate molecular assays to detect respiratory bacterial infection. The NeoPlex RB-8 detection kit (NeoPlex RB-8) is a new multiplex real-time PCR assay that simultaneously detects Streptococcus pneumoniae, Mycoplasma pneumoniae, Chlamydophila pneumoniae, Legionella pneumophila, Haemophilus influenzae, Bordetella pertussis, Bordetella parapertussis, and Moraxella catarrhalis in a single test. This study compared the clinical concordance of NeoPlex RB-8 with another method, Seeplex PneumoBacter ACE detection assay (Seeplex PB ACE), which simultaneously detects S. pneumoniae, M. pneumoniae, C. pneumoniae, L. pneumophila, H. influenzae, and B. pertussis We tested 2,137 nasopharyngeal swab and sputum specimens using both assays. For discordant Bordetella parapertussis and M. catarrhalis specimens, we also performed bidirectional sequencing. For S. pneumoniae, M. pneumoniae, C. pneumoniae, L. pneumophila, H. influenzae, and B. pertussis, which are detected by both NeoPlex RB-8 and Seeplex PB ACE, the positive and negative agreement between the two assays ranged from 91.7 to 100% (κ = 0.918 to 1). S. pneumoniae and H. influenzae were the most discordant targets and measured with higher sensitivity and specificity by NeoPlex RB-8 than Seeplex PB ACE. For Bordetella parapertussis and M. catarrhalis, which are not detected by Seeplex PB ACE, NeoPlex RB-8 sensitivity and specificity were >99%. Overall, NeoPlex RB-8 was highly comparable to Seeplex PB ACE, but NeoPlex RB-8 was more clinically accurate, with higher throughput and more convenience.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Reagent Kits, Diagnostic / Respiratory Tract Infections / Bacteria / Bacterial Infections / Multiplex Polymerase Chain Reaction Type of study: Diagnostic_studies / Evaluation_studies Limits: Humans Language: En Journal: J Clin Microbiol Year: 2020 Document type: Article Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Reagent Kits, Diagnostic / Respiratory Tract Infections / Bacteria / Bacterial Infections / Multiplex Polymerase Chain Reaction Type of study: Diagnostic_studies / Evaluation_studies Limits: Humans Language: En Journal: J Clin Microbiol Year: 2020 Document type: Article Country of publication: United States