Your browser doesn't support javascript.
loading
High-Throughput UHPLC-MS/MS Measurement of Per- and Poly-Fluorinated Alkyl Substances in Human Serum.
Mottaleb, M Abdul; Petriello, Michael C; Morris, Andrew J.
Affiliation
  • Mottaleb MA; Division of Cardiovascular Medicine, The Gill Heart and Vascular Institute, Superfund Research Center and Center for Appalachian Research in Environmental Sciences, University of Kentucky College of Medicine, Lexington Veterans Affairs Medical Center, Lexington, KY 40536, USA.
  • Petriello MC; Division of Cardiovascular Medicine, The Gill Heart and Vascular Institute, Superfund Research Center and Center for Appalachian Research in Environmental Sciences, University of Kentucky College of Medicine, Lexington Veterans Affairs Medical Center, Lexington, KY 40536, USA.
  • Morris AJ; Institute of Environmental Health Sciences and Department of Pharmacology, Wayne State University, Detroit, MI 48202, USA.
J Anal Toxicol ; 44(4): 339-347, 2020 May 18.
Article in En | MEDLINE | ID: mdl-31776573
ABSTRACT
Per- and poly-fluorinated alkyl substances (PFASs) are a large group of synthetic surfactant chemicals with widespread uses in food packaging and textile manufacturing and as the main constituent of aqueous film-forming firefighting foams. PFASs are highly persistent in the environment, and human exposures are extensive with these chemicals detectable in the blood of almost all adult Americans. PFASs exhibit a range of toxic effects in preclinical models. In humans, PFAS exposure has been associated with lower birth weights, decreased immune responses, cancer and impaired fertility and elevated circulating cholesterol levels. We have developed a sensitive high-throughput method for quantification of representative PFAS in human serum and plasma for biomonitoring and epidemiological studies of human health effects of PFAS exposure. The method combines robust and reproducible 96-well plate format sample preparation with ultra-performance liquid chromatography-tandem mass spectrometry. The method was developed, validated and used for targeted measurements of eight short-/long-chain PFAS analytes in human serum. Targeted analytes were measured in 50 microliters of sample using mass-labeled internal standards. Mean spiked recoveries (n = 10) of target analytes for three tiers quality control (QC-low, QC-medium, QC-high) samples ranged from 70 to 127% with 2-14% relative standard deviation (RSD). The average spiked recoveries (n = 10) of surrogates were 79-115% with 8-12% RSD for QC-low, 90-123% with 7-12% RSD for QC-medium and 82-114% with 9-15% RSD for QC-high. The limit of detection for the target compounds was 0.05-0.04 ng/mL. The method was used to reveal regional differences in PFAS exposures in Kentucky residents receiving care at the University of Kentucky Hospitals.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Environmental Pollutants / Fluorocarbons Limits: Humans Language: En Journal: J Anal Toxicol Year: 2020 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Environmental Pollutants / Fluorocarbons Limits: Humans Language: En Journal: J Anal Toxicol Year: 2020 Document type: Article Affiliation country: United States