Rapid Analysis in Continuous-Flow Electrochemical Paper-Based Analytical Devices.
Pradela-Filho, Lauro A; Noviana, Eka; Araújo, Diele A G; Takeuchi, Regina M; Santos, André L; Henry, Charles S.
Affiliation
  • Pradela-Filho LA; Instituto de Química , Universidade Federal de Uberlândia , Av. João Naves de Ávila, 2121 , Minas Gerais , Uberlândia, MG 38400-902 , Brasil.
  • Noviana E; Department of Chemistry , Colorado State University , Fort Collins , Colorado 80523 , United States.
  • Araújo DAG; Department of Chemistry , Colorado State University , Fort Collins , Colorado 80523 , United States.
  • Takeuchi RM; Department of Pharmaceutical Chemistry, Faculty of Pharmacy , Universitas Gadjah Mada , Yogyakarta 55281 , Indonesia.
  • Santos AL; Instituto de Química , Universidade Federal de Uberlândia , Av. João Naves de Ávila, 2121 , Minas Gerais , Uberlândia, MG 38400-902 , Brasil.
  • Henry CS; Instituto de Química , Universidade Federal de Uberlândia , Av. João Naves de Ávila, 2121 , Minas Gerais , Uberlândia, MG 38400-902 , Brasil.
ACS Sens ; 5(1): 274-281, 2020 01 24.
Article in En | MEDLINE | ID: mdl-31898461
A simple and low-cost continuous-flow (CF) electrochemical paper-based analytical device (ePAD) coupled with thermoplastic electrodes (TPEs) was developed. The fast, continuous flow combined with flow injection analysis was made possible by adding two inlet reservoirs to the same paper-based hollow channel flowing over detection electrodes, terminating in a fan-shaped pumping reservoir. The upstream inlet reservoir was filled with buffer and provided constant flow through the device. Sample injections were performed by adding 2 µL of the sample to the downstream sample inlet. Differences in flow resistance resulted in sample plugs displacing buffer as the solution flowed over the working electrodes. The electrodes were fabricated by mixing carbon black and polycaprolactone (50% w/w). CF-TPE-ePADs were characterized with chronoamperometry using ferrocenylmethyl trimethylammonium as the electrochemical probe. Optimized flow rates and injection volumes gave analysis times roughly an order of magnitude faster than those of previously reported flow injection analysis ePADs. To demonstrate applicability, the CF-TPE-ePADs were used to quantify caffeic acid in three different tea samples. The proposed method had a linear range from 10 to 500 µmol L-1 and limits of detection and quantification of 2.5 and 8.3 µmol L-1, respectively. Our approach is promising for fabricating simple, inexpensive, yet high-performance, flow injection analysis devices using paper substrates and easy-to-make electrodes that do not require external mechanical pumping systems or complicated valves.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Flow Injection Analysis / Equipment Design / Electrochemical Techniques Language: En Journal: ACS Sens Year: 2020 Document type: Article Affiliation country: Brazil Country of publication: United States