Your browser doesn't support javascript.
loading
Validated HPLC Method for Quantification of a Novel Trk Inhibitor, Larotrectinib in Mice Plasma: Application to a Pharmacokinetic Study.
Tripathy, Harsha K; Nair Manju, S V; Zakkula, Ashok; Bestha, Ram Murthi; Dittakavi, Sreekanth; Mullangi, Ramesh.
Affiliation
  • Tripathy HK; Karnataka College of Pharmacy Bangalore, Medicinal Chemistry, Bangalore, India.
  • Nair Manju SV; Karnataka College of Pharmacy Bangalore, Medicinal Chemistry, Bangalore, India.
  • Zakkula A; Jubilant Biosys, DMPK, Bangalore, India.
  • Bestha RM; Jubilant Biosys, DMPK, Bangalore, India.
  • Dittakavi S; Jubilant Biosys, DMPK, Bangalore, India.
  • Mullangi R; Jubilant Biosys, DMPK, Bangalore, India.
Drug Res (Stuttg) ; 70(2-03): 101-106, 2020 Feb.
Article in En | MEDLINE | ID: mdl-31931548
ABSTRACT
Larotrectinib, is an orally active novel small molecule approved for the treatment of solid tumors in pediatrics and adult patients. It acts by inhibiting tropomyosin receptor kinase. In this paper, we report the development and validation of a high-performance liquid chromatography (HPLC) method for the quantitation of larotrectinib in mice plasma as per the FDA regulatory guideline. Plasma samples processing was accomplished through simple protein precipitation using acetonitrile enriched with internal standard (IS, enasidenib). The chromatographic analysis was performed using a gradient mobile phase comprising 10 mM ammonium acetate and acetonitrile at a flow-rate of 0.8 mL/min on an X-Terra Phenyl column. The UV detection wave length was set at λmax 262 nm. Larotrectinib and the IS eluted at 3.85 and 6.60 min, respectively with a total run time of 8.0 min. The calibration curve was linear over a concentration range of 0.20-5.00 µg/mL (r2=≥0.992). The intra- and inter-day precision and accuracy results were within the acceptable limits. Results of stability studies indicated that larotrectinib was stable on bench-top, in auto-sampler, up to three freeze/thaw cycles and long-term storage at -80°C. The validated HPLC method was successfully applied to a pharmacokinetic study in mice.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pyrazoles / Pyrimidines / Chromatography, High Pressure Liquid / Protein Kinase Inhibitors Type of study: Guideline Limits: Animals Language: En Journal: Drug Res (Stuttg) Year: 2020 Document type: Article Affiliation country: India Publication country: ALEMANHA / ALEMANIA / DE / DEUSTCHLAND / GERMANY

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pyrazoles / Pyrimidines / Chromatography, High Pressure Liquid / Protein Kinase Inhibitors Type of study: Guideline Limits: Animals Language: En Journal: Drug Res (Stuttg) Year: 2020 Document type: Article Affiliation country: India Publication country: ALEMANHA / ALEMANIA / DE / DEUSTCHLAND / GERMANY