Your browser doesn't support javascript.
loading
How does contrast-enhanced ultrasonography influence Bosniak classification for complex cystic renal mass compared with conventional ultrasonography?
Qiu, Xiaoying; Zhao, Qiyu; Ye, Zhengdu; Meng, Lang; Yan, Chunhong; Jiang, Tian-An.
Affiliation
  • Qiu X; Department of Ultrasonography.
  • Zhao Q; Department of Ultrasonography.
  • Ye Z; Department of Hepatobiliary and Pancreatic Surgery, The First Affiliated Hospital, College of Medicine, Zhejiang University, PR China.
  • Meng L; Department of Ultrasonography.
  • Yan C; Department of Ultrasonography.
  • Jiang TA; Department of Ultrasonography.
Medicine (Baltimore) ; 99(7): e19190, 2020 Feb.
Article in En | MEDLINE | ID: mdl-32049855
ABSTRACT
To analyze the degree and pattern of influence of contrast-enhanced ultrasonography (CEUS) on the Bosniak classification system for complex renal cystic mass as compared with conventional ultrasonography (US). One hundred two consecutive patients with complex renal cystic masses were retrospectively analyzed. The diagnostic performance of the Conventional US and CEUS were evaluated separately for malignant and benign lesions. The diagnostic concordance rates were calculated according to pathologic diagnoses. ROC curve analysis determined the confidence in the diagnostic accuracy by calculating the area under each ROC curve. Compared to the Conventional US, septae number, wall and/or septae thickness, solid component and the Bosniak classification changed in 17 (16.7%), 39 (38.2%), 31 (30.4%), and 67 (65.7%) patients as compared with 0 (0.0%), 21 (20.6%), 31 (30.4%), and 37 (36.3%) of the treatment strategy that changed after CEUS respectively. The diagnostic performance of CEUS showed overall higher in terms of sensitivity (100.0 vs 97.2%); specificity (90.9 vs 62.1%); positive predictive value (PPV) (85.7 vs 58.3%); negative predictive value (NPV) (100.0 vs 97.6%); and the concordance with pathology (kappa = 0.876 vs 0.515). CEUS had a higher diagnostic confidence (P < .05) according to the area under the ROC curve (AUC = 0.968 vs 0.799).CEUS performed better than the Conventional US in the diagnosis of complex renal cystic mass, and it might be considered as the first tool to evaluate a complex cystic renal mass, especially for these Bosniak III masses displaying the presence of hemorrhage or infection.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phospholipids / Sulfur Hexafluoride / Ultrasonography / Kidney Diseases, Cystic Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Medicine (Baltimore) Year: 2020 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phospholipids / Sulfur Hexafluoride / Ultrasonography / Kidney Diseases, Cystic Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Medicine (Baltimore) Year: 2020 Document type: Article