Effect of observation size and apparent diffusion coefficient (ADC) value in PI-RADS v2.1 assessment category 4 and 5 observations compared to adverse pathological outcomes.
Eur Radiol
; 30(8): 4251-4261, 2020 Aug.
Article
in En
| MEDLINE
| ID: mdl-32211965
OBJECTIVE: To compare observation size and apparent diffusion coefficient (ADC) values in Prostate Imaging Reporting and Data System (PI-RADS) v2.1 category 4 and 5 observations to adverse pathological features. MATERIALS AND METHODS: With institutional review board approval, 267 consecutive men with 3-T MRI before radical prostatectomy (RP) between 2012 and 2018 were evaluated by two blinded radiologists who assigned PI-RADS v2.1 scores. Discrepancies were resolved by consensus. A third blinded radiologist measured observation size and ADC (ADC.mean, ADC.min [lowest ADC within an observation], ADC.ratio [ADC.mean/ADC.peripheral zone {PZ}]). Size and ADC were compared to pathological stage and Gleason score (GS) using t tests, ANOVA, Pearson correlation, and receiver operating characteristic (ROC) analysis. RESULTS: Consensus review identified 267 true positive category 4 and 5 observations representing 83.1% (222/267) PZ and 16.9% (45/267) transition zone (TZ) tumors. Inter-observer agreement for PI-RADS v2.1 scoring was moderate (K = 0.45). Size was associated with extra-prostatic extension (EPE) (19 ± 8 versus 14 ± 6 mm, p < 0.001) and seminal vesicle invasion (SVI) (24 ± 9 versus 16 ± 7 mm, p < 0.001). Size ≥ 15 mm optimized the accuracy for EPE with area under the ROC curve (AUC) and sensitivity/specificity of 0.68 (CI 0.62-0.75) and 63.2%/65.6%. Size ≥ 19 mm optimized the accuracy for SVI with AUC/sensitivity/specificity of 0.75 (CI 0.66-0.83)/69.4%/70.6%. ADC metrics were not associated with pathological stage. Larger observation size (p = 0.032), lower ADC.min (p = 0.010), and lower ADC.ratio (p = 0.010) were associated with higher GS. Size correlated better to higher Gleason scores (p = 0.002) compared to ADC metrics (p = 0.09-0.11). CONCLUSION: Among PI-RADS v2.1 category 4 and 5 observations, size was associated with higher pathological stage whereas ADC metrics were not. Size, ADC.minimum, and ADC.ratio differed in tumors stratified by Gleason score. KEY POINTS: ⢠Among PI-RADS category 4 and 5 observations, size but not ADC can differentiate between tumors by pathological stage. ⢠An observation size threshold of 15 mm and 19 mm optimized the accuracy for diagnosis of extra-prostatic extension and seminal vesicle invasion. ⢠Among PI-RADS category 4 and 5 observations, size, ADC.minimum, and ADC.ratio differed comparing tumors by Gleason score.
Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Prostatic Neoplasms
Type of study:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limits:
Aged
/
Humans
/
Male
/
Middle aged
Language:
En
Journal:
Eur Radiol
Journal subject:
RADIOLOGIA
Year:
2020
Document type:
Article
Affiliation country:
Canada
Country of publication:
Germany